OPERATION
THE POWER
SUPPLY UNIT
3
4
1
2
1 HMI lamp ON.
or OFF checklight.
2 Rocker switch.
3 Mains checklight.
4 Circuit breacker.
(Checklight 1 off).
LIGHTING UNIT
(Checklight 1 on).
LIGHTING UNIT
39
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
All manuals and user guides at all-guides.com
2500W HMI FOLLOW SPOT
NON-FUNCTIONING DIAGNOSIS.
SYMPTOMS
Checklight 3 does
not light up when the
power supply unit is
connected.
No light in the
lantern side.
Rocker switch 2 in ON
position, checklight 1
is off.
Difficulty in lighting.
No light in the lantern side.
(Lantern alight).
No light in the zoom side.
Bad quality light beam.
No air aspired or exhausted in the
lamphouse.
TECHNICAL FILE

POSSIBLE CAUSES

Mains absence.
Lamp failure.
Automatic breaker and
transformer are OFF.
Badly adjusted Spark-
gap.
Bad contact. Harting plug
power supply / Lighting
unit.
Lantern bonnet badly
closed.
Lamp is badly mounted.
Failure to ignite
(ignition block, Spark-gap).
Colour changer unit
closed.
Gobo frame changer
badly positioned.
Iris cassette badly
remounted.
Reflector and lenses not
in good condition.
Dirty filters.
1013+
VALID SINCE : 30.07.02
REMEDIES
Check the mains and
cable connections.
Repeat the operation.
Turn ON the automatic
breaker 4 .
Refer to page 22.
Check the connections.
Make sure bonnet is
properly closed. Adjust the
position of the mini-circuit
breaker.
Check cables and lamp.
Refer to pages 14 and 16.
Refer to page 22.
Open colour unit at the
front of the lighting unit.
Check gobo frame.
Refer to page 24.
Refer to page 22.
Refer to page 24.