Fig. 2. Selecting duct location for humidistat.
Locating Closest 120V Electrical Outlet
• Select location with access to an outlet. If not
available, contact an electrician to have one installed.
• Make sure that the humidifier cord is adequate to
reach from the humidifier to the outlet.
• Make sure that the 20 ft (6.2m) of thermostat wire is
adequate to reach from the humidifier solenoid, to the
sail switch, to the humidistat.
Installing the Humidifier
WARNING
Hazardous Voltage
Can cause personal injury or equipment
damage.
Do not cut or drill into any air conditioning or
electrical accessory.
CAUTION
Sharp Edges Installation Hazard.
Can cause personal injury.
Wear gloves and safety glasses.
1. Turn off power to the air handing system at the cir-
cuit breaker.
2. Draw a level line on the plenum in the location
chosen for the humidifier. (Leveling assures optimal
humidifier performance.)
3. Locate the template (form number 69-1650
included in the box). For the HE220 model, cut
out the template along the dotted line.
4. Tape the template in position and trace around
the template.
5. Remove the template and carefully cut the rect-
angular opening.
6. Disassemble the humidifier; remove the cover and
take out the humidifier pad assembly. See Fig. 3.
RETURN
AIR
15 in. (381 mm)
MINIMUM
M12831
HE220, HE260 HUMIDIFIER AND INSTALLATION KIT
COVER
SIDEWALL
BY-PASS SIDEWALL
Fig. 3. Disassembling humidifier.
7. Make sure the humidifier housing is level, then posi-
tion it in the opening so the plastic tabs are in place
on the lower sheet metal edge of the opening. Use
pliers, as necessary, to flatten cut edges. See Fig.
4.
8. Secure the humidifier housing to the opening at the
top and bottom using sheet metal screws.
SHEET METAL
SCREWS (4)
PLASTIC
TABS (2)
DRAIN TUBING
Fig. 4. Installing humidifier on duct.
9. Use the 6 in. (155 mm) starter collar as a template
to mark the opening for the bypass.
10. Carefully cut the opening for a 6 in. (155 mm)
starter collar. See Fig. 5. Use a drill, punch or awl to
start the cut in the middle of the circle. Cut in an out-
ward spiral to assist in controlling the cut.
3
WATER
FEED NOZZLE
HUMIDIFIER
PAD ASSEMBLY
FRAME
HUMIDIFIER
HOUSING
WATER
FEED TUBE
DUCT
LEVEL
OPENING
TO AIR DUCT
M20171
69-2516EF—01
M12304A