Technical Data - Dometic GROUP WAECO MagicTouch MT100 Instructions De Montage Et De Service

Table des Matières

Publicité

_IA_MT100.book Seite 36 Freitag, 28. Mai 2010 9:04 21

Technical data

13
Technical data
Central locking switching current:
Indicator activation switching current:
Interior light switching current:
Convenience output switching current:
Central locking control time:
Indicator control time (On/Off):
Controller
Operating voltage:
Standby current consumption without
LED (accessory):
Standby current consumption with LED
(accessory):
Operating temperature:
Dimensions (L x W x H):
Hand-held transmitter
Frequency:
Range:
Battery type:
Operating temperature:
Dimensions (L x W):
Versions, technical modifications and delivery options reserved.
Certifications
The device has e12 certification and R&TTE certification.
12
36
max. 10 A
max. 2 x 5 A
max. 1 A
max. 10 A
optionally 0.7 s/3.0 s
1 x 2 s/2 x 0.75 s
9–15 V DC
approx. 3 mA
approx. 8 mA
–40 °C to +85 °C
86 x 74 x 24 mm
433.92 MHz
10 m–20 m
CR2032, 3 V
–20 °C to +60 °C
41 x 76 mm
MagicTouch MT100

Publicité

Table des Matières
loading

Table des Matières