Technical data

Type
Power supply AC (V)
Power supply DC (V)
Consumption (mA)
Radio signal power
869.5MHz (dBm)
Range of the 869.5MHz radio signal
in a free area (m)
GSM signal power
EGSM - 900MHz (dBm)
GSM signal power
DCS - 1800MHz (dBm)
Digital inputs (V DC max)
Relay outputs (V DC max)
Relay outputs (A max)
Maximum cable length
connected to the relay outputs (m)
Maximum cable length
connected to output 485 (m)
Operating temperature (°C)
RGSM001 RGSM001S
12 to 30
12 to 35
200
14
-
100
-
33
30
24
30
1
≤ 100
≤ 1000
-20 to 70
Connections
Before making any connections, YOU MUST DISCONNECT
THE MAINS POWER.
If the device is not powered by a Came control panel,
make sure that the supply voltage is provided with pro-
tection devices for currents greater than 1 A.
Where the device is connected to a CAME control panel
equipped with CRP via terminal A-B-GND, power the module
only from terminals 2-10 on the panel itself.
Connecting a single operator
Connect the module to the control board via terminals (10-2)
with a 2 x 0.5 PVC FROR cable ⓐ (length max. 3 m).
Connect the module to the terminals (A-B-GND) with an UTP
CAT5 - AWG24 cable ⓒ and, if the operator is set up to do so,
insert the RSE card ⓔ.
Please refer to the module compatibility table.
Connecting to several operators
Connect the module to one of the control boards on terminals
(10-2), using a PVC FROR 2 x 0.5 cableⓐ (max. length 3 m) and
make an RS-485 connection (in enter-exit mode) on terminals
(A-B-GND), using a UTP CAT5 - AWG24 cable ⓒ;
maximum length of the UTP CAT5 cable 1000 m.