count, said module and all of the devices associated with
it must be deleted from the account.
7 Antenna mount.
8 Antenna.
I RSE card, to be inserted in Came control panels.
Warning LEDs
LED key
Off
On
Flashes every three seconds,
Flashes once per second,
Flashes three times per second,
Flashes five times per second.
Warning key
❶ GSM LED (blue)
GSM Modem Off,
Not registered on the GSM network,
Registered on the GSM network,
Active GPRS connection.
❷ OUT1 LED (red)
Relay 1 open,
relay 1 closed.
❸ OUT2 LED (red)
Relay 2 open,
relay 2 closed.
❹ POWER LED (green)
Module is powered off,
Module powered up and configured/associated,
Module is not configured (only factory settings),
P1 button pressed.
❺ CONN LED (red)
Module connected to CAMEConnect,
Module not connected to CAMEConnect,
Firmware remote update underway.
Description of the terminals
IN1 - COM Input 1 (24V DC max) and common input.
IN2 - COM Input 2 (24V DC max) and common input.
OUT1
Relay 1, 30V DC - 1A (max) N.O.
OUT2
Relay 2, 30V DC - 1A (max) N.O.
GND
Interface 485 earth.
B
PIN B interface 485.
A
PIN A interface 485.
2
– Power supply.
10
+ Power supply.
Where the device is connected to a CAME control panel
equipped with CRP via terminal A-B-GND, power the module
only from terminals 2-10 on the panel itself.