MEMORY AND RESET FUNCTION

OPERATING PRINCIPLE
Valve supply voltage is always stabilized 24 V DC ±10 % with a maximum ripple factor of 10 %.
Definition of logic values:
low value (logic 0) :
high value (logic1) :
To avoid interference, unused bits should be connected to ground.
Output pressure according to bit combinations :
PIN
C D E F G H I K
LSB
0 0 0 0 0 0 0 0
1 0 0 0 0 0 0 0
0 1 0 0 0 0 0 0
1 1 0 0 0 0 0 0
0 0 1 0 0 0 0 0
1 0 1 0 0 0 0 0
0 1 1 0 0 0 0 0
1 1 1 0 0 0 0 0
0 0 0 1 0 0 0 0
1 0 0 1 0 0 0 0
0 1 0 1 0 0 0 0
1 1 0 1 0 0 0 0
0 0 1 1 0 0 0 0
1 0 1 1 0 0 0 0
0 1 1 1 0 0 0 0
1 1 1 1 0 0 0 0
0 0 0 0 1 0 0 0
. . . . . . . .
. . . . . . . .
. . . . . . . .
1 1 1 1 1 1 1 1
To calculate the output pressure in relation to the combinations of bits :
PMR ( MAP in english ) = maximum air pressure
N = decimal value of the bit combination (10100000 = 5)
16
All manuals and user guides at all-guides.com
0........6 V (must stay between 0 to 6 volts)
8........24 V (must stay between 8 to 24 volts)
OUTPUT PRESSURE
MSB
OUTPUT PRESSURE = (PMR / 255) x N
(PMR / 255) x 0
(PMR / 255) x 1
(PMR / 255) x 2
(PMR / 255) x 3
(PMR / 255) x 4
(PMR / 255) x 5
(PMR / 255) x 6
(PMR / 255) x 7
(PMR / 255) x 8
(PMR / 255) x 9
(PMR / 255) x 10
(PMR / 255) x 11
(PMR / 255) x 12
(PMR / 255) x 13
(PMR / 255) x 14
(PMR / 255) x 15
(PMR / 255) x 16
.
.
.
.
.
.
(PMR / 255) x 255