Installation Electrical; Important Safety Notice - S&P HTB-75 N Notice D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Fitting to a wooden beam
Four screws (H) are supplied together with safety washer's (I) for fitting the support plate (A) to a
wooden beam. The holes for the screws should not be of greater diameter than the diameter of the
screw. Ensure that the wooden beam is able to support the weight of the moving fan (minimum
25/40 Kg.) (Fig.4)
ASSEMBLY OF THE FAN
IMPORTANT: If you installing more than one fan, ensure that you do not mix the fan blade sets, even
though they are from the same ceiling fan model.
1.- Fit the blades with the angles as shown in figure 5
2.- Fit the blades (C) to the motor assembly and support (B) using the screws (D) and the safety
washers (E). Do not forget to use the felt protection washers between the blade and the motor
assembly to avoid possible noise. Repeat this process with the remaining blades. (Fig.6)
IMPORTANT: Be careful not to support yourself on the fan blades, as these could then become
unbalanced and cause vibration or shaking of the fan.
3.- Loosen the screws situated in the base of the decorative canopy to allow easier access to the
anchorage point and electrical connectors. Hang the motor and support assembly (B) from the hook
on the support plate (A) (previously fixed to the ceiling) (Fig.7)
4.- Connect the cables and position them correctly. The connections and the fitting point can be
hidden using the decorative canopy.

INSTALLATION ELECTRICAL

IMPORTANT SAFETY NOTICE: Before installation, ensure that the electrical supply is disconnected
at the mains junction / fuse box.
- The airflow direction can be changed depending upon the wiring connection configuration in
- All products are supplied, factory wired, for a downward airflow configuration.
- If the airflow direction is required to be changed on a frequent basis, then an airflow direction
switch should be installed as a separate additional accessory (Fig.9)
IMPORTANT: Before changing the direction of ariflow, the fan blades must have completely stopped
turning after switching the unit to the off position.
OPERATION INSTRUCTIONS
1. – The speed regulator has four positions.
0 .........OFF
1 ......... High speed
2 ......... Medium speed
3 ......... Low speed
All manuals and user guides at all-guides.com
accordance with (Fig.8)
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Htb-90 nHtb-150 n

Table des Matières