Technical Data; Troubleshooting; Spare Parts - Stiebel Eltron DHC 3-1 Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data

Model
Phase
Voltage
Wattage
Ampere
Min. required circuit breaker size A 30
Recommended wire size
AWG COPPER 10
Min. water flow
to activate unit
GPM / l/min 0.32 / 1.2
Pressure loss in unit
PSI / bar 2.88 / 0.23
Nominal water volume
Working pressure max.
Tested to pressure
Weight
lbs. / kg 4.6 / 2.1
Water connections
– Suitable for supply with cold water
– Tankless water heaters are considered a non-continuous load
– Conductors should be sized to maintain a voltage drop of less than 3 % under load

Troubleshooting

Symptom
No hot water but audible click can be heard
when water is turned on
No hot water and no audible click can be
heard when water is turned on
Water not warm enough
If you are not able to resolve a problem please contact us toll free at 800-582-8423 before removing the unit from the wall.
STIEBEL ELTRON is happy to provide technical assistance. In most instances, we can resolve the problem over the phone.

Spare parts

No. Spare part
1 Heating system
2 Flow switch
3 Thermostat
4 Switch
5 Housing (back)
6 Plumbing connection
7 Housing (front)
8 Safety thermal cut out
9 Wiring block
10 Copper tube
11 Module chassis
12 Wire strain relief clamp
DHC 3-1
DHC 3-2
1
1
V 120
208
240
kW 3.0
2.5
3.3
A 25
12
14
15
20
14
12
0.32 / 1.2
2.88 / 0.23
5.3 / 2.4
Possible cause
– circuit breaker off
– safety thermal cut-out tripped
– water flow too low to activate flow switch
– water flow too high
– voltage too low
Model DHC 3-1
DHC 3-2
16 58 89
16 77 69
16 52 73
16 52 73
16 24 72
16 80 26
16 58 91
17 07 89
16 58 92
16 24 74
16 22 02
16 50 49
16 23 14
16 24 62
05 57 54
DHC 4-2
DHC 4-3
DHC 5-2
1
1
1
208
240
277
208
2.9
3.8
4.5
3.6
14
16
17
18
20
20
20
30
12
12
12
10
0.42 / 1.6
0.42 / 1.6
0.42 / 1.6
2.88 / 0.23
2.88 / 0.23
2.88 / 0.23
0.13 GAL / 0.5 l
150 PSI / 10 bar
300 PSI / 20 bar
5.3 / 2.4
4.6 / 2.1
4.6 / 2.1
1/2" NPT
DHC 4-2
DHC 4-3
DHC 5-2
16 77 70
16 58 90
16 77 71
16 21 62
16 21 62
16 21 62
– 8 –
DHC 6-2
DHC 8-2
1
1
240
208
240
208
240
4.8
4.5
6.0
5.4
7.2
20
22
25
26
30
30
30
30
40
40
10
10
10
8
8
0.48 / 1.8
0.69 / 2.6
2.88 / 0.23
3.13 / 0.25
5.3 / 2.4
5.3 / 2.4
Solution
– circuit breaker on.
– reset thermal cut-out
.
– clean faucet aerator.
– open shut-off valve completely.
– open flow adjustment screw
– clean filter screen at DHC unit
– reduce water flow, close flow adjustment
screw
.
– supply correct voltage to unit.
DHC 6-2
DHC 8-2
17 11 17
16 77 72
17 11 05
16 21 64
DHC 10-2
1
208
240
7.2
9.6
35
40
40
50
8
8
0.79 / 3.0
3.75 / 0.30
5.3 / 2.4
.
.
DHC 10-2
16 77 73
16 21 65

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dhc 3-2Dhc 4-2Dhc 4-3Dhc 5-2Dhc 6-2Dhc 8-2 ... Afficher tout

Table des Matières