Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
3.

FACTORY SETTINGS

The C
is supplied in a Current Controller configuration as standard.
D
ontrol
AscoDigiCom files for the Current Controller configuration (standard), a simple Process Controller configuration and a
Cascaded Process Controller configuration are included on the supplied CD-ROM.
The following configurations and pinnings apply for the supplied AscoDigiCom files:
Open-loop control
Voltage supply
+24V or +12V
Voltage supply
GND
PE
Setpoint
0 - 10 V
Setpoint
GND
Coil
+
Coil
0V
Closed-loop control
Voltage supply
+24V or +12V
Voltage suply
GND
PE
Sensor supply
+24V or +12V
Sensor input
0 - 10 V
Sensor supply
GND
Setpoint
0 - 10 V
Setpoint
GND
Solenoid valve coil
+
Solenoid valve coil
0V
Cascade or double-loop process control
Voltage supply
+24V or +12V
Voltage supply
GND
PE
Sensor supply
+24V/+12V
Sensor input 1*
0 - 10 V
Sensor supply 1*
GND
Sensor supply (1-2)
+24V or +12V
Sensor input 2**
0 - 10 V
Sensor supply 2**
GND
Setpoint
0 - 10 V
Setpoint
GND
Solenoid valve coil
Solenoid valve coil
* Slave loop sensor (1)
** Master loop sensor (2)
If you have any questions on the configuration or parameter settings of this product, please contact our Product Support
by email at product.support@emerson.com or phone (+49) 7237-996-676.
Pin 1
Pin 2
Pin 3
Pin 11
Pin 12
Pin 15
Pin 16
Pin 1
Pin 2
Pin 3
Pin 5
Pin 6
Pin 7
Pin 11
Pin 12
Pin 15
Pin 16
Pin 1
Pin 2
Pin 3
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 15
Pin 16
Control
D
offers 3 control modes
PWM* Signal
Setpoint
Control
D
offers 3 control modes
PWM* Signal
Open loop control
Setpoint
PWM*
Setpoint
Proportional
Solenoid Valve
Signal
Open loop control
Closed loop control
PWM*
Setpoint
Proportional
PWM*
Solenoid Valve
Proportional
Setpoint
Signal
Solenoid Valve
Signal
Closed loop control
Double loop control
PWM*
Proportional
Setpoint
PWM*
Solenoid Valve
Set-
Signal
Proportional
Master
Slave
point
Solenoid Valve
Signal
Control
D
offers 3 control modes
Double loop control
PWM* Signal
Comparator
*PWM: pulse-width modulated
PWM*
Set-
Proportional
Setpoint
Master
Slave
point
Solenoid Valve
Signal
Open loop control
Comparator
*PWM: pulse-width modulated
Setpoint
PWM*
Proportional
Solenoid Valve
Signal
Closed loop control
Setpoint
PWM*
Proportional
Solenoid Valve
Signal
Double loop control
PWM*
Set-
Proportional
Master
Slave
point
Solenoid Valve
Signal
Comparator
*PWM: pulse-width modulated
DP-IM14152-7
GB
Process
Process
Process
Process
Process
Process
Process
Process
Process

Publicité

Table des Matières
loading

Produits Connexes pour Asco ControlD

Ce manuel est également adapté pour:

603001176030011860300119

Table des Matières