Delectrical Connections; Important - GE PCP912 Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D
ELECTRICAL CONNECTIONS
D1
TURN OFF POWER
Turn off power at the circuit breaker or remove
fuses to the cooktop branch circuit.
CONNECT TO JUNCTION BOX
D2
With the cooktop in place, open the cabinet
door and complete the electrical connections
to the junction box. When making the wire
connections, use the entire length of conduit
provided. The conduit must not be shortened.
INSERT WIRES
D3
Insert the wires from the conduit through the
opening of the junction box.
Red
Ground
Installation Instructions
Black
CONNECT LEADS
D4
Connect the red and black leads from the
cooktop conduit to the corresponding leads
in the junction box.
Ground wire
location
SECURE WIRES TOGETHER
D5
Once the connections are made, secure the
wires together using wire nuts.
Ground
GROUNDING INSTRUCTIONS:
The bare ground wire in the conduit is
connected to the cooktop frame.
If connecting to a 4-conductor branch circuit,
installing in a mobile home or recreational
vehicle, or if local codes do not permit
grounding through the neutral white lead, attach
the appliance grounding lead (green or copper)
to the residence grounding conductor (green or
bare copper) in accordance with local codes.
When connecting to a 3 conductor branch circuit,
if local codes permit, connect the bare ground
connector lead of the cooktop to the branch
circuit neutral (gray or white in color).

IMPORTANT:

being installed into a blind counter
(one with no cabinet opening below),
wire connections must be made before putting
the cooktop into the cutout opening.
6
Red
Black
Red
Strain relief
clamp
Black
If the cooktop is

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pcp932Jcp346

Table des Matières