10.1 - OIL CHECK AND CHANGE

• The oil level must be checked periodically thr ough the oil sight glass
• Oil must be changed after the first 50 hours of operation of the machine. Subsequent oil
changes must be carried out every 300 hours of machine operation.
• In any case it is advisable to change the oil at least once a year .
• Oil type: SAE 15W40 MINERAL
• Oil capacity: 0,33 liters T series
0,40 liters TX series
• Unscrew the drain plug on the bottom of the pump and the black/yellow dipstick on top.
• Collect the used oil in a tank and convey it to an authorized collection center .
• Replace the drain plug and fill in the oil up the level as shown in the oil level gauge.
• Replace the black/yellow dipstick.
T
TX

10.2 - INLET FILTER

Before using the machine it is IMPOR TANT to make sur e that the filter is clean. W ash the fil-
ter under running water and/or with an air pr essure gun to totally eliminate any deposits in the
filter.
Remember that a clean filter guarantees the good of the machine operation.
Clean the filter using an air
Clean the filter under run-
Remove the filter from the
pressure gun.
ning water.
water inlet

10.3 - REPLACEMENT OF HIGH PRESSURE NOZZLE

Periodically it is necessary to r eplace the high pressure nozzle as this is a component subject
to normal wear during use. This wear can generally be noticed by a decr ease of the working
pressure. Contact your dealer if you wish to pur chase a new nozzle.