Operating Specifications; Installation Instructions - Omnifilter BF9C Informations D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING SPECIFICATIONS

Pressure Range:
Temperature Range:
Rated Flow:
PRECAUTIONS
WARNING
Risk of electrical shock. If your water pipes are
used to ground your house's electrical system, install a No. 8
AWG jumper wire (or larger) around the filter (see Figure 6). The
jumper wire must be connected at both ends by a pressure wire
fitting or other connection that satisfies NEC or CEC and local
codes.
WARNING
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system.
CAUTION
Filter must be protected against freezing, which can
cause cracking of the filter and water leakage.
CAUTION
The rubber O-ring provides the water-tight seal
between the cap and the bottom of the housing. It is important
that the O-ring be properly seated in the groove above the
threads of the housing or a water leak could occur.
CAUTION
Because of the product's limited service life and to
prevent costly repairs or possible water damage, we strongly
recommend that the bottom of all plastic housings be replaced
every ten years. If the bottom of your housing has been in use
for longer than this period, it should be replaced immediately.
Date the bottom of any new or replacement housing to indicate
the next recommended replacement date.
CAUTION
Do not use electrical heating tape on this unit.
NOTES:
For cold water use only.
The contaminants or other substances removed or reduced by
this water treatment device are not necessarily in your water.
Ask your local water municipality for a copy of their water
analysis, or have your water tested by a reputable water
testing lab.
Do not install where system will be exposed to direct sunlight.
Filter cartridge life varies depending on filter type, usage, and
water conditions.
The replacement filter cartridge used with this system has a
limited service life. Changes in taste, odor, or flow of the water
being filtered indicate that the cartridge should be replaced.
Use only OMNIFILTER replacement cartridges.
This installation must comply with all applicable state and
local regulations.
Use only plumber tape without adhesive backing to seal joints.
Do not use pipe compound ("pipe dope"), sticks, or similar
compounds with this unit; they contain petroleum derivatives
which will cause crazing and cracking of the plastic in the filter
housing.
Use only soap and water to clean filter housing
and components.
• 2 •
All manuals and user guides at all-guides.com
Do not use aerosol sprays (bug spray, cleaning fluids, etc.)
near the filter. They contain organic solvents which will cause
30–100 psi
crazing and cracking of the plastic in the filter housing.
40°F–100°F
After prolonged periods of non-use, such as a vacation, it
is recommended that the system be flushed thoroughly. Let
15 gpm
water run for 5-6 minutes before using.
Do not use a torch near the unit.
Some harmless bacteria may attack cellulose media cartridges
such as the RS15 and TO8. If your cartridge seems to
disintegrate or develops a musty or moldy odor, switch to a
synthetic media cartridge or consult the manufacturer.
Wear safety glasses during installation.

INSTALLATION INSTRUCTIONS

NOTE:
Please read all instructions, specifications, and precautions
before installing and using your water filter.
There must be a shut-off valve before the filter.
Install filter after water meter or pressure tank.
Numbered diagrams correspond with numbered steps.
Before installing the filter, determine where the unit will be
located and what type of pipe the unit will connect to. The filter
head has 1-inch NPT threaded connections molded into it. The
distance from the top of the water piping to the floor must be
at least 15-inches for filter change allowance. Allow a 1
clearance below the housing to allow for changing the cartridge.
The recommended installation has a shut-off valve on both the
inlet and outlet sides of the filter. The installation shown uses
copper piping. The weight of the filter should be supported so it
does not stress the pipes. The main house water shut-off valve
can be used as the inlet side shut-off valve.
-inch
1
2
Suggested installation

Publicité

Table des Matières
loading

Table des Matières