EDM Product 08790 Manuel D'instructions page 60

Pompe à eau submersible
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

cations provided in the technical data.
ES
▶ Check the mains socket for its proper condition and sufficient
fusing.
▶ Make it impossible for moisture to reach mains plug or socket.
PT
THERE IS A RISK OF ELECTRIC SHOCK!
EN
FR
1. Fasten the supplied nylon cord to the transport
handle (1) at the top of the device. (see fig. 10)
2. Lower the device into the water at a slight angle
to allow any remaining air to escape. (see fig. 11)
fig. 10
3. If you want the device to be positioned on the
ground, ensure that the latter is even.
4. Attach the nylon cord to an easily accessible
position, so you can pull the device back out after
pumping has been completed.
Instruction manual
Warning of electrical voltage
Electric shock from damaged power supply cable.
Make sure not to hold or suspend the device by the
power supply cable under any circumstances.
Note
At the bottom of ponds and other waterbodies depo-
sits may have accumulated over time. To prevent the
device from being damaged, do not lower it all the
way to the ground unless you are certain that the
water is clean, in other words that the size of the dirt
particles in the water does not exceed 5mm.
fig. 11
Ref. 08790 / Ref. 08791

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

08791

Table des Matières