EDM Product 08790 Manuel D'instructions page 58

Pompe à eau submersible
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ES
3. When using a hose without thread:slide an appropriate
hose clamp onto the hose.
4. Push the hose (inner diameter 25mm or 32mm) onto the
PT
reducer (7) all the way to the stop. (see fig. 6)
5. Affix the hose by means of the hose clamp.
6. When using a hose with internal thread (1''): screw the
EN
hose connection onto the reducer 7. (see fig. 7)
7. Alternatively, you can also screw a hose with Internal
threading (1 ½") directly onto the elbow (8) or adapter (9).
FR
PIPE
If possible, screw the pipe directly into theconnection with 1  ½" 
internal thread (6) or use a suitable adapter. (see fig. 8)
Adjusting the float switch
The device comes equipped with a float switch (4) which switches
the device on or off automatically according to the water level.
Check the float switch (4) for proper functioning at regular intervals.
SWITCHING POINT
Height for switch-on
Height for switch-off
Instruction manual
fig. 7
Ref. 08790
Approx. 500mm
Approx. 250 mm
Ref. 08790 / Ref. 08791
fig. 8
WATER LEVEL
Ref. 09791
Approx. 500mm
Approx. 250mm