OPERATING INSTRUCTIONS Continued
Pressing the FAN HIGH key will activate the higher fan speed
and light its LED.
Pressing the FAN LOW key will activate the lower fan speed
and light its LED.
Pressing the FAN PULSE key will activate the lower fan speed
and light its LED. The fan will be active for 30 seconds then
off for 30 seconds, and continuous this cycle.
Pressing the SETBACK key will cool the oven cavity to
a preprogrammed temperature, see: Setting "Set-Back"
Feature. The oven will automatically go into Setback mode
after the pre-programmed non-usage time. The display will
indicate "SETB". This is an energy-saving feature.
Pressing the COOL DOWN key will deactivate the heat, turn
the fan on high and light its LED. This display will indicate
"OPEN DOOR" if the door is closed, prompting the user
to open the door slightly. With the door open slightly the
display will indicate "COOL". The Cool down will operate
when the door is closed or opened slightly. Optimal cool-
down will be achieved with the door open slightly. When
the door opens wider, the Cool Down mode will deactivate
and the display will indicate "DOOR". This is a patented safety
feature. Pressing the COOL DOWN key again will turn the
LED off and stop this mode. Pressing the ON/OFF key will
also cancel Cool down. Cool Down is not active during a
cook.
When the ON/OFF switch is pressed to turn the oven off and
the oven was above 200°F (93°C), the oven will go into an
AUTO COOL DOWN mode. In Auto cool Down, the oven will
run the fan on high until the oven cavity drops below 150°F
(66°C). During this time the display will indicate "AUTO".
When the oven temperature drops below 150°F (66°C) the
oven turns off . This feature protects the oven motor from
premature failure. Optimal cool-down will be achieved with
door open slightly.

Fahrenheit/Celsius

Factory default is Fahrenheit (F). To change to
Celsius (C), press and hold in the "Phantom Key" located
to the right of "Cook/Hold" key. "F" appears in the display.
Continue to hold until "C" is displayed and then release the
"Phantom key".