5.12. Clean the air entrance pipe.
5.13. Clean the convector and the interior of the convection chamber. A dirty convector or a dirty convection
chamber will reduce the performance of the stove and may cause overheating alarms.
5.14. Review the glass door joints.
Review in detail any imperfections which may cause an air inlet. Replace them if necessary.
5.15. Cleaning the dirt which may be accumulated inside the stove, accessing through the back.
5.16. Empty the hopper to take remaining pellets out to avoid pellets absorb humidity.
IMPORTANT: After cleaning or fixing, make sure the stove operates correctly. Once you turn the stove off or
during the seasons when you do not use it, disconnect the stove to avoid electronic damages.
It consists in controlling the combustion air inlet and gas outlet; make sure nothing prevents normal
circulation (e.g. bird nests). The gas outlet must also be inspected for possible water infiltrations.
In addition, it is recommended to clean the base of floor of the stove, the back side of the stove that you
reach through the back grid or lateral doors, in order to take eventual dust away that might have stacked during
summer time.
6.
PROBLEMS AND RECOMMENDATIONS.
6.1.
Do not turn the stove on and off successively because this might damage the electronical components and
motors ~230/240V - 50Hz.
6.2.
Do not touch the stove while your hands are wet. Though the stove is equipped with ground plug, it remains
an electric machine that could cause electric discharge if handled incorrectly. A qualified technician only shall
resolve the eventual problems.
6.3.
Do not remove any screw of the zones exposed to high temperature before they have been lubricated
properly with lubrication oil.
THE STOVE REMAINS OUT OF POWER:
6.4.
Make sure the stove is connected and the plug is leading power.
6.5.
Make sure the cable is not damage or cut.
While the stove is disconnected, dismantle the right side of the stove and check if any lead of the C.P.U. is
slack.
6.6.
Check the C.P.U pilot. If it is OFF, check also the fuse on the C.P.U.
PELLETS DO NOT FALL AND THE STOVE DOES NOT TURN ON:
6.7.
Check if there are pellets in the hopper.
6.8.
Make sure the glass door is closed.
6.9.
Make sure the gas outlet tube is not obstructed by anything (e.g. bird nest, plastic, etc.).
6.10. Make sure the exhaust motor works, because if it does not work fuel will not fall.
6.11. If the reducer motor does not rotate and the displays indicates the pulses, the first thing to do will be unplug
the stove and verify if the safety thermostat has been activated. With the stove unplugged, check that the
safety thermostat is located inside the stove, by opening the right side. To activate it, you must press the
CHECKING AT BEGINNING OF SEASON.
WHAT NOT TO DO.
WHAT DO TO IF...