fadini Elpro 980 Manuel page 9

Masquer les pouces Voir aussi pour Elpro 980:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Elpro 980
GB
ELECTRICAL CONNECTIONS FOR 1 BAYT 980 TO THE
ELPRO 980 PROGRAMMER
The main assembly Cos 982, voltage disconnector, limit
switches and blue led light are factory pre-set.
LOW VOLTAGE ELECTRIC CONNECTIONS
Accessory
Photocells or
magnetic loops
IN I
F A D
Keyswitch
F A
D I
N I
F A
D I
N I
Limit Switches
2 8
9 9
ELECTRONIC CONTROL BOARD FOR ROAD BARRIERS BAYT 980
Electrical connections
1 2
CONTACT FOR
24 V OUTPUT (MAX. LOAD 350 mA:
PHOTOCELLS OR
N° 2 PAIRS PHOTOCELLS
MAGNETIC LOOPS
N° 1 RADIO RECEIVER)
3 4 5 6
NO
NO
NC
8 9 10
LIMIT SWITCH
LIMIT SWITCH
CLOSING
OPENING
LIMIT SWITCH
COMMON
TRAFFIC LIGHTS
WITH 3 LAMPS
63 64 65 66 60 61
Fuse 1 A
Red
Yellow
Green
External
power supply
230 V - 50 Hz
FLASHER
230 V - 25 W max
Drive unit COS 982
12 13
9
1
2
3
4
5
6
7
8
9
10
1 2 3 4 5 6 7 8 9 10 11 12 13
F1
PHASE
NEUTRAL
F2
COMMON
Dip-Switch setting and LED indication of functions
DIP-SWITCH N° 1:
ON: photocells or loop stop beam on opening
reverse on closing once obstacle is removed
OFF: photocells or loop do not stop beam on
1
opening, reverse on closing in case of an obstacle
DIP-SWITCH N° 9:
ON: on dwell, automatic mode (Dip-Switch 3 = ON)
the beam lowers on crossing the 2
photocells or loop
9
OFF: no beam lowering on crossing 2
photocells
11 12 13
27 28 29
23 24
27 28 29
23 24
F3
nd
pair
nd
pair

Publicité