Elpro 980
GB
ELECTRICAL CONNECTIONS FOR 2 BAYT 980s TO ELPRO 980 PCBs
Important: before completing all of the electrical connections
as required, identify the Elpro 980 of the master barrier, which
!
commands the Elpro 980 in the slave barrier.
In the case of simultaneous barriers it is suggested that they
are set with an equal barrier beam length and speed,
otherwise the master barrier between the two must be that
with the longer barrier beam length or that with the slowest
speed.
• Elpro 980 master: perform all of the connections necessary for the operation of the Bayt 980; any command accessories, radio PCB etc. must be
connected exclusively to the Elpro 980 master.
• Elpro 980 slave: power the PCB, jump the NC connections (stop, photocell and safety switches) and finally connect the motor and the limit switches
of the Bayt 980 slave. Set the dip-switch 12 = ON.
• Connect the 27, 28, 29 terminals of the Elpro 980 master respectively with the 3, 4, 5 terminals of the Elpro 980 slave.
1
2
3
4
5
6
7
63 64 65 66 60 61
1
2
3
Fuse 1 A
Red
Yellow
Green
Traffic lights PCB
PHASE
NEUTRAL
COMMON
ELECTRONIC CONTROL BOARD FOR ROAD BARRIERS BAYT 980
Important: carry on the inter-connections
!
between the two Elpro 980 master and
slave PCBs
8
9 10
11 12 13
27 28 29
27 28 29
23 24
4
5
6
7
8
9 10 11 12 13
Elpro 980 master PCB
23 24
1
2
3
Traffic lights
PCB connector
PHASE
NEUTRAL
COMMON
Plug-on
radio receiver
connector
11
4
5
6
7
8
9 10
11 12 13
1
2
3
4
5
6
7
8
9 10 11 12 13
Elpro 980 slave PCB
23 24
23 24
Plug-on
radio receiver
connector