TROUBLESHOOTING (cont.)
The LCD or remote
control does not react.
Visible External
Monitoring / Test
Indication LED does
not flash.
Visible External
Monitoring / Test
Indication LED (red)
flashes continuously
Door cycles open and
remains open
• IXIO sensors are intended to be used with pedestrian sliding door systems.
• This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the
instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 7 of 8
The sensor is protected by
a password.
Monitoring installation/set-
up error.
Sensor and/or wiring
malfunction.
Wiring issue
Control not set correctly
Door control monitoring
set to Active High
Enter the correct password. If you forgot the
code, cut and restore the power supply to access
the sensor without entering a password during
1 minute.
Verify door control is capable of monitoring
and the sensor monitoring wires are properly
connected to the door control.
Verify monitoring (TEST) is on in the sensor
settings.
Verify that there are no breaks anywhere in the
wire harness.
Replace the sensor.
Verify wiring.
Verify control monitoring set to Active Low.
Set door control monitoring to Active Low.