SET-UP
SET-UP 1 (QUICK)
reference picture
either hold the knob for 2 seconds, or use the
remote control buttons as specified
SET-UP 2 (ASSISTED)
test of full door cycle + reference picture
either hold the knob for 4 seconds, or use the
remote control buttons as specified
OVERVIEW OF SETTINGS
Back
More
AIR: WIDTH
+
AIR: OUTPUT
TEST
More
Back
Back
More
RAD: HOLDTIME
RAD: OUTPUT
AIR: IMMUNITY
AIR: WIDTH
+
AIR: NUMBER
AIR: PRESENCE TIME
AIR: FREQ
AIR: OUTPUT
TEST
REDIRECTION
FACTORY RESET
More
Back
ZIP CODE
all parameter settings in zipped format
(see application note on ZIP CODE – 76.0024)
ID #
unique ID-number
CONFIG P/N
SOFT P/N
ERROR LOG
last 10 errors + day indication
Page 5 of 8
STEP OUT OF THE INFRARED FIELD!
TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
0
1
2
3
DeEner/NO
Energ/NC
Energ/NC
Energ/NC
DeEner/NO
Energ/NC
off
on
Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control.
0.5 s
1 s
2 s
3 s
DeEner/NO
Energ/NC
Energ/NC
Energ/NC
DeEner/NO
Energ/NC
normal
enhanced
1
2
30 s
1 min
A
B
DeEner/NO
Energ/NC
Energ/NC
Energ/NC
DeEner/NO
Energ/NC
off
on
Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control.
aux
presence
+
presence
factory value
+
4
5
6
7
DeEner/NO
DeEner/NO
The sensor LED will briefly flash RED during monitoring communication with door control.
4 s
5 s
6 s
7 s
DeEner/NO
DeEner/NO
mode B
2 min
5 min
10 min
20 min
DeEner/NO
DeEner/NO
The sensor LED will briefly flash RED during monitoring communication with door control.
AIR: SPOTVIEW
AIR: C1 ENERG
AIR: C2 ENERG
POWERSUPPLY
OPERATINGTIME
RESET LOG
PASSWORD
ADMIN
+
+
8
9
Always additionally adjust the
arrow position on the sensor with a
DeEner: De-Energized relay
Energ: Energized relay
This indicates that external monitoring is functional.
8 s
9 s
DeEner: De-Energized relay
Energ: Energized relay
Always additionally adjust the
arrow position on the sensor with a
min. value for DIN18650: 1 min
60 min
infinte
min. value for EN16005: 30 s
DeEner: De-Energized relay
Energ: Energized relay
This indicates that external monitoring is functional.
0 presence detection on safety input
1 presence detection on safety + auxilary inputs
full
partial
partial: outputs are not reset
reset
reset
view of spot(s) that trigger detection
signal amplitude received on curtain 1
signal amplitude received on curtain 2
supply voltage at power connector
power duration since first startup
delete all saved errors
LCD and remote control password
(0000= no password)
enter code to access admin mode
75.5782.09 IXIO-ST UL 20180305
2 s
OR
4 s
OR
screwdriver.
NO: normally open
NC: normally closed
NO: normally open
NC: normally closed
screwdriver.
NO: normally open
NC: normally closed