BEA IXIO-ST Guide D'installation page 4

Masquer les pouces Voir aussi pour IXIO-ST:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1
MOUNTING & WIRING
Use the provided mounting template and mount the sensor, ensuring that the bottom of the sensor is within 2
Route the harness using the harness clip as shown in the exploded view of the mounting illustration.
Mounting is compatible with the WIZARD.
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains
voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness.
2
INFRARED SAFETY FIELD
OR
Activate the visible* spots to verify the
position of the AIR-curtain.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 8 in.
Part of the detection field can be masked to reduce its width
The arrow position determines the width of the detection field.
Page 4 of 8
inches of the bottom of the door header.
Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.
CLOSER
AWAY
If necessary, adjust the AIR-curtain angle
(from -7° to 4°, default 0°).
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
Always verify the actual detection field width by
walk-testing according to ANSI 156.10 guidance.
Additional adjustments are possible by
LCD or remote control (see OVERVIEW OF
SETTINGS).
The size of the detection field varies according to the mounting height and the settings of the sensor.
12-24 V AC, 50/60 Hz
12-24 V AC, 50/60 Hz
12-30 V DC
12-30 V DC
Max 2.5 W
Max 2.5 W
* Output status when sensor is operational.
** The sensor LED will briefly flash RED during monitoring communinication
with door control. This indicates that external monitoring is functional.
Monitoring functionality must be active on the sensor and monitoring wires
must be properly connected to the door control.
RED
POWER SUPPLY
BLACK
BROWN
SAFETY INPUT
BLUE
WHITE
OPENING INPUT
YELLOW
GREEN
PURPLE
TEST OUTPUT**
PURPLE
Mounting
Detection
height
6' 6"
7'
"
3
16
8'
"
3
16
9'
"
13
16
11' 6"
The full door width must be covered.
75.5782.09 IXIO-ST UL 20180305
DOOR
max.
3 in**
width
6' 6"
7'
"
3
16
8'
"
3
16
d max
d max

Publicité

Table des Matières
loading

Table des Matières