The torque applied to motor 1 during braking in the opening phase is ad-
Pso1
justed *
The torque applied to motor 1 during braking in the closing phase is ad-
Psc1
justed *
The torque applied to motor 2 during braking in the opening phase is ad-
Pso2
justed *
The torque applied to motor 2 during braking in the closing phase is ad-
Psc2
justed *
It adjusts the operating time of the service light when the "Service Light"
TLS
logics is preset to ON and the "2nd radio channel" logics is preset to
OFF
* WARNING: An incorrect setting of these parameters may result in an hazard. Comply with regulations in force!
To check the torque applied to the various phases of the operation, proceed as follows:
With switched-off display and moving gate leaves, press and keep the <+> key pressed
Two figures separated by a dot are displayed (e.g. 52.55), the first two figures indicate the torque applied to motor 1, while the
last two the torque applied to motor 2.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter
IbL
impulse has no effect during the opening phase.
Off: condominium function disabled.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the
SCL
intervention of the photocell causes automatic closing after 3 s. Active only
with TCA:ON.
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the
transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
The "service light" function is enabled or disabled on terminals (9-10)
On: output, enabled as "Service light". This output is activated at the beginning
SERL
of each operation and remains activated for the time preset by parameter TLS.
Off: output, enabled as "Open gate light".
This function is not enabled if the "2°Ch radio" logics is preset to ON.
The second radio channel is enabled or disabled on terminals (9-10).
On: "2
Off: "2
2ch
as "Service light" if SERL=On, or as SCA if SERL=Off.
If this function is preset to On, any presetting of the SERL logics will be ig-
nored.
The OPEN Input mode is preset.
On: OPEN Input, with CLOCK function.
To be used as connection to timer for timed opening/closing. (Closed contact:
CLOC
gate open. Open contact: normal operation).
Off: OPEN input, with OPEN function.
This function is activated only if the OPCL logics=ON
The Step-by-Step and Pedestrian input modes is selected.
On: Input to terminal 18 activated as OPEN. Input to terminal 17 is activated
OPCL
as Closed.
Off: Input to terminal 18 activated as Step-by-Step. Input to terminal 17 acti-
vated as Pedestrian.
14
radio channel" output is enabled.
nd
radio channel" output is disabled. The output to terminals is activated
nd
FUNCTION
1-99-(20%)
1-99-(20%)
1-99-(20%)
1-99-(20%)
2s-180s-(60s)
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
OFF
(OFF)
(OFF)
(OFF)