  • FRANÇAIS, page 18
CN3
Accessory power supply connection 24Vac 15 watts max
13)
2nd radio channel connection (only if using 2-channel radio connector)
14)
2nd radio channel connection (only if using 2-channel radio connector)
15)
Antenna connection (signal)
16)
Antenna connection (mesh)
17)
24Vac Max 10 Watt
18)
24Vac Max 10 Watt
JP3
JP3 1)
Capacitor
JP3 2)
Capacitor
JP4
Connection of Motor
19)
opening
20)
shared
21)
closing
CN4
25)
Signal encoder
26)
Supply encoder
27)
Negative encoder
JP5
Motor limit switch connection
22)
limit switch closing NC
23)
common connection
24)
limit switch opening NC
N.B. The LEDs that correspond to the limit switches are ON when the relative limit switch is not involved.
1 2 3 4 5
M
13
6 7 8 9 10 11 12 13 14 15 16 17 18
21
20
19
25 26 27
22 23 24
NO