CN1
dedicated to the connection of the power supply of the board:
1) N
230Vac
2) F
230Vac
3) L.C.
Courtesy light max.25W 230Vac
4) COM LC/LP
Shared courtesy light or flasher
5) LMP
Connected to the flasher max.25W 230Vac
CN2
6) $
Connected to the earth of the system
7) PED
Pedestrian function Contact N.O. Normally open
It is an opening command which when activated will partially open the door.
8) P/P
Step/step operation
Connected between Term. N.8 and Term. N.12 Contact N.O
Control input open/close or open/stop/close based on selection of parameter D
9) F1
Photocell Close Function
Connected between Term. N.9 and Term. N.12 Contact N.C.Normally Closed
This input is considered a safety, the contact can be interrupted at any time during closing of the automation caus-
ing an immediate stop in movement and reversing the direction of movement
10) F2
Photocell Open Function
Connected between Term. N.10 and Term. N.12 Contact N.C. Normally closed
This input is considered a safety, the contact can be interrupted at any time during opening by the automation caus-
ing an immediate stop in movement, the automation will continue until the contact is restored.
11) STP

Stop function

Connected to Term. N.11 and Term. N.12 Contact Normally Closed N.C. This input is considered a safety the con-
tact can be interrupted at any time immediately stopping the automation disabling any function including automatic
closing.
12) COM
TX
RX
F1
24Vac/dc
24Vac/dc
-
-
+
1 2
3
1 2
1 2 3 4 5
230Vac
1 2 3 4 5
TX
+
NC
3 4
24Vac/dc
-
+
1 2
3
6 7 8 9 10 11 12 13 14 15 16 17 18
6 7 8 9 10 11 12 13 14 15 16 17 18
NA PED
NA P/P
RX
F2
24Vac/dc
NC
-
+
1 2
3 4
12
RG58
NC STOP