Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

OnePower
UPS 600VA/300W
A03-PE601
MANUAL
A03-PE601 _MX01
Where solutions begin
Company certified ISO 9001:2000

Publicité

Table des Matières
loading

Sommaire des Matières pour Atlantis Land OnePower A03-PE601

  • Page 1 OnePower UPS 600VA/300W A03-PE601 MANUAL A03-PE601 _MX01 Where solutions begin Company certified ISO 9001:2000...
  • Page 2 Italiano fare riferimento al sito www.atlantis- land.com. ENGLISH This product is covered by Atlantis Land 3 years On-Site warranty. For more detailed informations please refer to the web site www.atlantis- land.com. For more detailed instructions on configuring and using this device, please refer to the online manual.
  • Page 3 Where solutions begin Company certified ISO 9001:2000...
  • Page 4: Table Des Matières

    OnePower UPS 600VA/300W ITALIANO 1.1 Introduzione al prodotto 1.2 Verifica Iniziale 1.3 Contenuto della confezione 1.4 Collocazione 1.6 Test di Funzionamento 1.7 Pannello frontale 1.8 Le porte posteriori 1.9 Sostituzione Batterie APPENDICE A: RISOLUZIONE DEI PROBLEMI A.1.1 Problematiche dell’UPS A.1.2 Batterie e Fusibile APPENDICE B: SUPPORTO OFFERTO ENGLISH 1.1 Important Safety Instructions...
  • Page 5 OnePower UPS 600VA/300W FRANCAIS 1.1 Introduction 1.2 Vérification 1.3 Dans la boîte 1.4 Mise en place 1.7 Facade 1.8 Face arrière 1.9 Changement de Batterie APPENDICE A: PROBLEMES A.1.1 Problèmes A.1.2 Batterie et Fusible APPENDICE B: ASSISTANCE TECHNICAL FEATURES BACKUP TIME A03-PE601_MX01 (V1.0 November 2005)
  • Page 6 Atlantis Land spa. Tutti i nomi di produttori e dei prodotti e qualsiasi marchio, registrato o meno, menzionati in questo manuale sono usati al solo scopo identificativo e rimangono proprietà...
  • Page 7 ATTENZIONE! E’ opportuno leggere attentamente questo manuale prima dell’installazione e della messa in servizio del gruppo di continuità Atlantis Land. La garanzia decade se non vengono rispettate tutte le norme e le prescrizioni indicate nel presente manuale operativo. L’UPS può essere riparato solo da personale qualificato.
  • Page 8: Introduzione Al Prodotto

    OnePower UPS 600VA/300W(IT) 1.1 Introduzione al prodotto Seguire attentamente tutte le istruzioni durante l’installazione. Leggere attentamente l’intero manuale prima di iniziare l’installazione del dispositivo. 1.2 Verifica Iniziale Controllare immediatamente il dispositivo. Rivolgersi al rivenditore qualora il dispositivo fosse danneggiato. La confezione in cartone è in materiale riciclabile e andrebbe conservata e utilizzata per proteggere il prodotto durante eventuali spedizioni.
  • Page 9: Collocazione

    OnePower UPS 600VA/300W(IT) 1.4 Collocazione Al fine di evitare rischi di incendi o shock elettrici, disporre l’apparato in ambiente indoor con temperatura ed umidità controllate e privo di agenti conduttori di ogni genere. Si ricorda inoltre che: • L’UPS è da usarsi esclusivamente in ambienti chiusi (indoor) •...
  • Page 10 OnePower UPS 600VA/300W(IT) Attenzione: Per garantire l’integrità ed il corretto funzionamento del gruppo di continuità, non collegare mai all’uscita dell’UPS fotocopiatrici, stampanti laser, utensili elettrici o qualsiasi altro tipo di carico induttivo. E’ possibile vedere in figura un esempio di cablaggio completo. A03-PE601 Pag.
  • Page 11: Test Di Funzionamento

    OnePower UPS 600VA/300W(IT) 1.6 Test di Funzionamento 1. Collegare l’UPS alla rete elettrica. 2. Tenere premuto pulsante di accensione (immediatamente il LED line si accenderà di verde) sino a che il LED non si spegne (a questo punto è possibile rilasciare il bottone). Dopo qualche secondo (terminata la fase di autotest) il LED Line ( ) si accenderà...
  • Page 12 OnePower UPS 600VA/300W(IT) LED/Bottone Informazione Per accendere/spegnere l’UPS quando la rete elettrica è Main Switch ( presente. Accensione: tenere premuto per circa 3 secondi sino a che il LED Line non si spegne, quindi rilasciare il bottone di accensione (a questo punto, dopo la fase di autotest, l’UPS sarà...
  • Page 13: Le Porte Posteriori

    OnePower UPS 600VA/300W(IT) 1.8 Le porte posteriori Identificativo Utilizzo Connettore di ingresso per la rete elettrica. Prese IEC di back-up. Collegare a queste prese gli apparati che devono essere alimentati dalla batteria in caso di black- out o altre anomalie sulla rete elettrica. Fusibile di protezione (4A/250Vac).
  • Page 14 OnePower UPS 600VA/300W(IT) Prima di iniziare la sostituzione della batteria è opportuno spegnere l’UPS e staccarlo dalla rete elettrica. 1. Utilizzare un cacciavite a stella per rimuovere le 2 viti poste nella parte inferiore del pannello frontale. Aprire delicatamente il dispositivo. 2.
  • Page 15: Appendice A: Risoluzione Dei Problemi

    OnePower UPS 600VA/300W(IT) APPENDICE A: Risoluzione dei problemi Questo capitolo illustra come identificare e risolvere eventuali problemi riscontrati con l’utilizzo del dispositivo. A.1.1 Problematiche dell’UPS I LEDs ed i segnali acustici sono un utile strumento per individuare eventuali problemi, osservandone lo stato e/o ascoltandone il tipo di beep è possibile individuare velocemente un eventuale malfunzionamento.
  • Page 16: A.1.2 Batterie E Fusibile

    Si raccomanda di sostituire le batterie una volta all’anno. Dove posso 1. Un qualunque negozio specializzato. 2. Chiederle direttamente all’assistenza tecnica di Atlantis Land. trovare batterie per la sostituzione? Staccare innanzitutto il prodotto dalla rete elettrica e sfilare Come verifico delicatamente l’alloggio portafusibile (identificativo N°...
  • Page 17: Appendice B: Supporto Offerto

    A. Per qualunque altro problema o dubbio è possibile contattare l’help desk telefonico (02/93907634) gratuito di Atlantis Land (munirsi di serial number e codice prodotto presente sul retro dell’ups) che fornirà assistenza da lunedì al giovedì...
  • Page 18: Fcc Information

    OnePower UPS 600VA/300W(EN) Copyright The Atlantis Land logo is a registered trademark of Atlantis Land SpA. All other names mentioned mat be trademarks or registered trademarks of their respective owners. Subject to change without notice. No liability for technical errors and/or omissions.
  • Page 19 OnePower UPS 600VA/300W(EN) Caution: Risk of electric shock, hazardous live parts inside this UPS can be energized from the battery supply even when the input AC power is disconnected. Caution: Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground.
  • Page 20: Important Safety Instructions

    OnePower UPS 600VA/300W(EN) 1.1 Important Safety Instructions This manual contains important safety instructions. Please follow all instructions carefully during installation. Read this manual thoroughly before attempting to unpack, install or operate. 1.2 Inspection Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The package is recyclable;...
  • Page 21: Placement

    OnePower UPS 600VA/300W(EN) 1.4 Placement To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants. • This UPS system is designed for indoor use only. • Do not install the UPS under direct sunlight. Your warranty will be void if the batteries fail due to overheating.
  • Page 22 OnePower UPS 600VA/300W(EN) Caution: Do not connect a laser printer to the outlets. These UPS outlets provide battery power and surge protection to the equipment when utility voltage is outside acceptable limits. A03-PE601 Pag. 17...
  • Page 23: Operation Test

    OnePower UPS 600VA/300W(EN) 1.6 Operation Test 1. Connect the UPS to the wall receptacle. 2. Push on the Main Switch till the Green LED ( ) is extinguished, release the Main Switch, then the UPS self-test is being performed. The UPS is in normal status, and the Green LED ( ) is ON.
  • Page 24 OnePower UPS 600VA/300W(EN) LED/Button Information To Control on/off the UPS when Utility is normal. Push Main Switch ( the "Main Switch" for 3 seconds, then release it when the LED is extinguished To enable “DC-Start” Function when Utility fails. (To enable DC Start properly, you are recommended to connect <80% output load with the UPS only).
  • Page 25: Rear Panel Explanations

    OnePower UPS 600VA/300W(EN) 1.8 Rear Panel Explanations Number Explanations AC Inlet Backup Outlets: 3pcs IEC320 AC Fuse Holder. (W/fuse) (4A/250Vac). Sticker with details on the product. 1.9 Replacing the Battery The Following Precautions Should be Observed When Working on Batteries: •...
  • Page 26 OnePower UPS 600VA/300W(EN) 1. Use a cross-type screwdriver to remove the two screws and slide down the panel. 2. Gently Pull the battery out of the UPS. 3. Loosen the black wire from the negative (-) terminal and red wire from the positive (+) terminal.
  • Page 27: Appendix A: Trouble Shooting

    Switch On/Off pushed turn ON/OFF. longer than 3 seconds or not. No LEDs display Contact Atlantis Land. on the front panel 1. The UPS’s battery is weak 1. Charge the battery. does due to recent outage. 2. If the battery is near the end provide expected 2.
  • Page 28: A.1.2 Battery And Fuse

    Where can I 1. please contact Your reseller. 2. please contact directly Atlantis Land. find batteries? Check the fuse to be sure it is not blown or damaged. Also, make sure the fuse makes good contact and is not loose in check the fuse holder.
  • Page 29: Appendix B: Support

    If you have any problems with the UPS, please consult this manual. If you continue to have problems you should contact the dealer where you bought this device. If you have any other questions you can contact the Atlantis Land company directly at the following address: Atlantis Land SpA...
  • Page 30 OnePower UPS 600VA/300W(FR) Copyright Copyright. 2002 est la propriété de cette société. Tout droits réservés. Sont interdites, la reproduction, la transmission, la transcription, la mémorisation dans un système de sauvegarde où la traduction dans une autre langue ou en langage informatique quels qu’ils soient, de la présente publication, sous quelque forme que ce soit ou quelque en soit le moyen, électronique, mécanique, magnétique, optique, chimique, manuel ou de tout autre genre, sans avoir obtenu...
  • Page 31 OnePower UPS 600VA/300W(FR) émettre de l’énergie en fréquences radio. S’il n’est pas installé et utilisé conformément aux instructions, il peut provoquer des perturbations des communications radio. L’absence de perturbations ne peut cependant pas être garantie pour une configuration donnée. Si l’appareil perturbe la réception de la radio ou de la télévision (ce qui peut être déterminé...
  • Page 32 OnePower UPS 600VA/300W(FR) • tenir les outils avec du matériel isolant; • porter gants en gomme et bottes; • ne pas toucher la batterie avec un objet en métal; A la sortie de l’UPS il peut y avoir une tension de 220V même lorsqu’il n’est pas connecté...
  • Page 33: Introduction

    Ce manuel contient d’importantes informations de sécurité. Suivez attentivement les instructions pendant l’installation. Nous vous prions de lire attentivement ce manuel avant l’installation et la mise en service de votre onduleur Atlantis Land, en vous rappelant que la garantie n’est plus valable si toutes les normes et les prescriptions indiquées dans ce manuel ne sont pas respectées.
  • Page 34: Mise En Place

    OnePower UPS 600VA/300W(FR) 1.4 Mise en place Pour prévenir les risques de feu ou de choc électrique, installez dans une pièce dont la température et l’humidité sont contrôlées. • Cet UPS ne doit être utilisé qu’à l’intérieur. • Ne pas l’installer à un endroit directement exposé au soleil, la garantie serait annulée en cas de surchauffe de la batterie.
  • Page 35: Reliez Les Charges

    OnePower UPS 600VA/300W(FR) 1.5 Reliez les charges Connectez en premier l’UPS au secteur, puis branchez les appareils à l’UPS. Pour utiliser l’UPS comme interrupteur “On/Off”, veillez à mettre sur “On” tous les appareils. Attention : Pour garantir l’intégrité et le fonctionnement correct, ne jamais brancher à...
  • Page 36: Opérations De Test

    OnePower UPS 600VA/300W(FR) 1.6 Opérations de Test 1. Connectez l’UPS au secteur. 2. Appuyez sur le bouton (pour 3/4 secondes) M/A jusqu'à que la LED est éteinte. A ce stade l’UPS est bien initialisé (verifier que la LED Ligne ) est allumée). 3.
  • Page 37: Face Arrière

    OnePower UPS 600VA/300W(FR) mettre le mode secours (DC-Start), de plus une fois le mode Secours activé, il ne faut pas brancher de nouveau périphérique. Eclairage continu en fonctionnement. LED Ligne ( Clignote avec alarme sonore toutes les 2 secondes en mode secours (batterie).
  • Page 38 OnePower UPS 600VA/300W(FR) • tenir les outils avec du matériel isolant; • porter gants en gomme et bottes; • ne pas toucher la batterie avec un objet en métal; •A la sortie de l’UPS il peut y avoir une tension de 220V même lorsqu’il n’est pas connecté...
  • Page 39: Appendice A: Problemes

    OnePower UPS 600VA/300W(FR) APPENDICE A: Problèmes Lorsque l’onduleur ne fonctionne pas correctement, avant de vous adressez au service après vente, consultez ce chapitre. A.1.1 Problèmes Les LEDs et les signaux sonores sont des indicateurs utiles pour déterminer d’éventuels problèmes, en observant l'état et/ou en écoutant les beep il est possible de déterminer rapidement un éventuel mauvais fonctionnement.
  • Page 40: A.1.2 Batterie Et Fusible

    OnePower UPS 600VA/300W(FR) disponible? secteur, rebranchez le puis présent, l’UPS est faites le démarrer. en fonction, mais il ne fonctionne (led Ligne n’est pas fixe). A.1.2 Batterie et Fusible Question Solution Durée pendant laquelle l'UPS peut maintenir le bon Durée du focntionnement de la charge avant le déchargement complet secours de la batterie.
  • Page 41: Appendice B: Assistance

    APPENDICE B: Assistance Pour tous problèmes ou renseignements vous pouvez contacter la « help desk » téléphonique gratuite d’Atlantis Land qui vous fournira assistance du: lundi au vendredi de 9.00 à 13.00 et 14.00 à 18.00 Vous pouvez aussi nous contacter par email : tech-fr@atlantis-land.com Atlantis Land France 57, Rue d’Amsterdam...
  • Page 42: Technical Features

    OnePower UPS 600VA/300W Technical Features Power Rating(VA) Power Rating(W) INPUT Voltage: 185-265V [230Vac +15%, -20%] Frequency: 50Hz±5% OUTPUT Voltage: AC: 185-265V [230Vac +15%, -20%] INV: 214-246V [230Vac ±7%) Frequency: 50Hz (±1%) Waveform Simulated SineWave TRANSFER Line/Battery Less than 5 ms (typical) EFFICIENCY Total Efficiency Over 80% BATTERY...
  • Page 43: Backup Time

    OnePower UPS 600VA/300W Backup TIME PentiumIV 3.0 Ghz + LCD 17” PentiumIV 3.2 Ghz + LCD 17” PentiumIV 3.4 Ghz + LCD 19” Power Rating(VA) Power Rating(W) Backup Time(minute) A03-PE601 Pag. 38...
  • Page 44 Atlantis Land S.p.A. Viale De Gasperi, 122 Mazzo di Rho – MI – Italy info@atlantis-land.com sales@atlantis-land.com Where solutions begin Company certified ISO 9001:2000...

Table des Matières