Technical Information - Hansgrohe Solaris E 06633 0 Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Information

Recommended water pressure
Max. water pressure
Recommended hot water temp.
Max. hot water temp
Hole size in mounting surface
Max. mounting surface depth
Flow rate
Requires 1/2" supply lines (not included)
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
Installation
Install the hot and cold valves
Install the mounting nut, metal washer and the fiber
washer on the valve.
Insert the valve through the hole in the deck. The
hot valve is marked with a red dot.
Install the stop ring on the valve. Thread the mount-
ing plate on the valve until the stop ring stops it at
the proper height.
Rest the valve on the mounting surface. Turn the
valves so that the outlets point toward the center.
Tighten the mounting nut. Tighten the tensioning
screws.
Install the spout
Swing C and Limbo C only: Place the sealing
ring, deco-ring, and spout on the mounting surface.
All other models: Place the sealing ring and
spout on the mounting surface.
14.7 - 72.5 psi
147 psi
120° - 140°F*
165°F*
1 1/4" valves, 1 3/8" spout
1 1/2"
1.5 gpm
3

Publicité

Table des Matières
loading

Table des Matières