Windsor High Efficiency Wood Insert
Clearance to Combustible Constructions
1. Remove all boxes of firebricks and any packaging from
inside the appliance.
2. Clean out the masonry fireplace ensuring the ashes
are placed in a metal container.
3. Remove or lock open the damper plate in the masonry
fireplace.
4. Contact local building, fire officials or authorities hav-
ing jurisdiction about permits, restrictions and installa-
tion inspection requirements in your area.
Figure 2
Clearance to Combustibles
4
Installation
Mantel
Top Trim
Face Plate
Floor Protector
A
Clearance to Combustible Constructions
ST1022
A
Unit to Side Wall
DW2500 clearances
B
Unit to Top Trim
10/08
C
Unit to Side Trim
D
Unit to Mantel
E
Floor Protector Front
F
Floor Protector Side
Refer to Page 6 for Floor Protection requirements
5. The insert must be installed in compliance with the
minimum clearances to combustible constructions and
floor protection stated on appliance certifications la-
bel (located on back of unit) and listed below. Refer to
Page 5 for further instructions about floor protection.
fAILURE to foLLoW tHESE MInIMUM CLEARAnC-
ES REQUIREMEntS MAy RESULt In An UnSAfE In-
StALLAtIon.
6. Install the refractory bricks. (Fig. 3)
7. Install faceplate onto insert. (Page 7) The trim should
fit against the face of the fireplace. If this is not a good
fit, a 2" (51 mm) wide strip of fiberglass insulation can
be used to insure a good fit.
D
B
C
Floor
F
12" (305 mm)
10" (254 mm)
10" (254 mm)
17" (430 mm)
16" (405 mm) in the US
18" (457 mm) in Canada
8" (203 mm)
12"
(305 mm)
Max
E
ST1022
30005129