Mechanical installation
Arrangement of the devices
5.3
Arrangement of the devices
4
Fig. 5−1
A DC−bus connection with regenerative power supply module has to be planned and
dimensioned taking the technical data into account.
How to arrange the devices for operation in the DC−bus connection via the DC busbars:
Arrange the devices in a row from left to right.
ƒ
Install the supplying device on the left:
ƒ
– Regenerative power supply module with assigned mains filter (in a first row),
– Input module (in the following rows).
Install the multi drive axis controllers to the right from the highest to the lowest
ƒ
power (recommendation).
For increasing the braking power also single drive axis controllers can be integrated.
ƒ
For this purpose, these axis controllers have to be equipped with the optional busbar
mounting set (E94AZJAxxx). In order to carry out multi−supply applications, consult
Lenze.
42
L1
L2
L3
+
...
M
M
3~
3~
+UG
-UG
...
M
M
15
4
3~
3~
Arrangement concept
E94AZMR0xx4xDB
Mains filter
E94ARNE0xx4
Regenerative power supply module
(with E94AZPP0364 installation backplane)
E94AZEX100
DC−input module
E94AZPxxxxx
installation backplane for 9400 axis module
+UG/−UG
DC bus
l
+UG
-UG
+UG
-UG
94ANGVR01
EDK94ZMR47XDB DE/EN/FR/ES/IT 4.0