3.1. ENvIRONMENtAL cONDItIONS

indoor use.
operating range
Storage range
degree of pollution
altitude

3.2. MEcHANIcAL SPEcIFIcAtIONS

Pistol-grip Kelvin probe
„ dimensions
grip
probe
thickness
„ diameter of the probes
„ center-to-center distance between the probes 3.5 mm
„ travel of the probes
„ lead
„ Spaded lugs
„ Safety terminals
„ Mass
„ resistance
Straight Kelvin probe with rotation
„ dimensions (l x W x h)
„ diameter of the probes
„ center-to-center distance between the probes 8 mm
„ travel of the probes
„ lead
„ Spade lugs
„ Safety terminals
„ Mass
„ resistance
protection index
ip 40 according to iec 60 529
iK 04 according to iec 50102
drop test
according to iec 61010-1

3.3. ELEctRIcAL SAFEty

electrical safety according to iec 61010-031
Maximum current: 10a
Maximum voltage: 30V

3. SPEcIFIcAtIONS

-10 °c to +55 °c and 10 % to 85% rh
-40 °c to +70 °c and 10 % to 90% rh
2
< 3000 m
108 x 40 mm
154 x 30 mm
28 mm
2 mm
7 mm
3.15 m long
for diameters from 4 to 6 mm
diameter of 4 mm
approximately 2 x 420 g
approximately 2 x 40 mΩ
207 x 34 x 30 mm
3 mm
10 mm
3.15 m long
for diameters from 4 to 6 mm
diameter of 4 mm
approximately 2 x 400 g
approximately 2 x 35 mΩ