LEGRAND Y4262B Mode D'emploi page 20

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Register
Register
Register
Address
Address
Number
(Dec)
(Hex)
16386
16385
4001
16387
16386
4002
16388
16387
4003
16389
16388
4004
(16389)
(16388)
(4004)
(16389)
(16388)
(4004)
(16389)
(16388)
(4004)
(16389)
(16388)
(4004)
(16389)
(16388)
(4004)
(16389)
(16388)
(4004)
16390
16389
4005
20481
20480
5000
20482
20481
5001
20483
20482
5002
20484
20483
5003
20485
20484
5004
29185
29184
7200
29186
29185
7201
29187
29186
7202
29188
29187
7203
29189
29188
7204
29190
29189
7205
29192
29191
7207
(29192)
(29191)
(7207)
(29192)
(29191)
(7207)
(29192)
(29191)
(7207)
(29192)
(29191)
(7207)
(29192)
(29191)
(7207)
(29192)
(29191)
(7207)
29193
29192
7208
29194
29193
7209
29195
29194
720A
(29195)
(29194)
(720A)
(29195)
(29194)
(720A)
(29195)
(29194)
(720A)
(29195)
(29194)
(720A)
(29195)
(29194)
(720A)
29196
29195
720B
29198
29197
720D
29199
29198
720E
20
Dimension
Bit
[word]
Position
1
Operation counter
1
Reserved (gives a fixed value)
1
Breaker features - Rated current
1
Breaker features - Breaker type and poles
3÷0
Poles: number
4
Poles: neutral position - (0 = right; 1 = left)
7÷5
Reserved (gives a fixed value)
8
Breaker type: 0 = switch disconnector; 1 = automatic)
9
Breaker type: 0 = not repulsive; 1 = repulsive)
15÷10
Reserved (gives a fixed value)
1
Breaker features - Breaking capacity
1
Phase 1 current
1
Phase 2 current
1
Phase 3 current
1
Neutral current
1
Ground current
1
Overload tripped relay counter
1
Short circuit tripped relay counter
1
Instantaneous tripped relay counter
1
Ground fault tripped relay counter
1
Over-temperature tripped realy counter
2
Buffer last intervention data - Value
1
Buffer last intervention data - Cause
0
Overload tripping - (0 = not tripped, 1 = tripped)
1
Short circuit tripping - (0 = not tripped, 1 = tripped)
2
Instantaneous tripping - (0 = not tripped, 1 = tripped)
3
Ground fault tripping - (0 = not tripped, 1 = tripped)
4
Over-temperature tripping - (0 = not tripped, 1 = tripped)
15÷5
Reserved (gives a fixed value)
1
Main setting - overload: upper limit
1
Main setting - overload: delay
1
Main setting - overload: options
0
Reserved (gives a fixed value)
1
Unit of measure (0 = %, 1 = A)
4÷2
Curve (000: I2t=k MEM ON, 001: I2t=k MEM OFF)
7÷5
Reserved (gives a fixed value)
15÷8
Working point
2
Main Setting – short circuit delay: upper limit
1
Main Setting – short circuit delay: delay
1
Main Setting – short circuit delay: options
Description
Scale
Unit
1
1
1
A
100
kA
1
A
1
A
1
A
1
A
1
A
1
1
1
1
1
1
mA, °C
1
A
1
msec
1
A
1
msec