Optional Extras - BFT ARES VELOCE SMART BT A500 Instructions D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Logic
Definition
Configuration of
EXPI1 input on
input-output ex-
EXPI1
pansion board.
1-2
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
4-5
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
TRAFFIC
Traffic light pre-
LIGHT PRE-
flashing
FLASHING.
TRAFFIC LIGHT
Steadily lit red
RED LAMP
light
ALWAYS ON
INSTALLATION MANUAL
Cross out
De-
setting
fault
used
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
11
movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
1
12
movement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is
13
switched automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
14
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/
15
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched
16
automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing
17
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening
18
the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety
device test input, EXPFAULT1.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
0
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
11
movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
12
movement stops.
0
Output configured as 2
1
Output configured as SCA (gate open light).
11
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light.
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
11
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
11
Output configured as Traffic Light control with TLB board.
0
Pre-flashing switched off.
0
1
Red lights flash, for 3 seconds, at start of operation.
0
Red lights off when gate closed.
0
Red lights on when gate closed.
1

Optional extras

nd
Radio Channel.
31
ARES VELOCE SMART BT A500
-

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ares veloce bt a500

Table des Matières