ERRORS
Display
Type of error
ERROR 1
Incorrect password
ERROR 2
Code not found or memory position free
ERROR 3
Repeated code: shows the memory position of the programmed code. A sound signal is issued.
ERROR 4
Position occupied: jumps to the first free position. A sound signal is issued.
ERROR 5
Data outside range
ERROR 6
Lack of space available in memory for the range selected or memory full. A sound signal is issued.
ERROR 7
Memory error: memory card not inserted, erroneous or with incorrect format (from other equipment).
ERROR 8
Events error: events card incorrect or with incorrect format (from other equipment).
OPTIONAL ANTI-PASSBACK CARD OPERATIONS
Card connections
Connect the anti-passback card to the controller, disconnecting the power supply.
Operations
The Anti-passback provides access and exit control, preventing a user from accessing consecutively in the same direction. The user
must access only once in each direction (entry and exit).
The Anti-timeback is a timed anti-passback and allows for access twice consecutively in the same direction after the selected time.
Operations with transmitters
Magnetic sensors must be used for card operations with transmitters to be able to distinguish the entry and exit of vehicles to and
from an installation. Therefore, the card includes three terminals (presence contact normally open for entry and exit and common)
for the connection of sensors.
Warning: to validate entry access, one must be located on the entry loop and press the transmitter at the same time. To validate
exit access, one must be located on the exit loop and press the transmitter at the same time.
Operations with access control devices
In this case, magnetic sensor connection is optional (where not used, leave the terminals unconnected).
Modes
If you work at MODE 1, the configuration will be the following: channel 1 for entry, channel 2 for exit. The channels 3 and 4 will be
free and they will not be controlled by the anti-passback.
If you work at MODE 2, the configuration will be the following: channel 1 et 3 for entry, channel 2 et 4 for exit.
USE OF THE CONTROLLER
These equipments are designed for the remote control of garage doors, to send the activation commands to control panels and to
activate/deactivate alarm systems. Its use is not guaranteed for directly activating equipments other than those specified.
The manufacturer reserves the right to modify equipment specifications without prior notice.
1247005v1-2.indd 25
1
2
3
4
5
25
1
Detection indication Leds
2
EXIT presence contact
3
ENTRY presence contact
4
Common
5
Connect card to controller