Télécharger Imprimer la page

JCM Technologies ACCESS-1000 Mode D'emploi page 19

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
TECHNICAL FEATURES
Frequency
Coding
Memory
Events
Number of relays
Anti-panic function
Alarm function
Power supply
Range at 12V dc
Range at 12V ac
Relay contacts
Standby / Op. Consumption
Battery
Access control outlet
(Max. 4 readers without external power supply)
Op. temperature
Watertightness
Dimensions
Box dimensions
INSTALLATION AND CONNECTIONS
Fit the rear of the box to the wall using the rawlplugs and screws supplied. Pass the cables through the bottom of the equipment.
Connect the power supply cables to the terminals on the printed circuit, following the indications engraved on the board. Close the
lid on the equipment using the screws supplied.
OPERATING
The name of the controller, the programme version and the date and time will appear on the screen when the equipment is switched on.
Upon receiving a code, the equipment checks whether it is in its memory, enabling the programmed relay/s. The position in the
memory held by the code received and by the relay/s enabling the channel sent by the device are displayed on the screen.
If the device code is not recorded in the memory, the controller will remain motionless and the message "NO" will appear on the
screen.
MENUS
Press any key to enter the menu and the controller will ask for the password. Enter the 4-digit password using the numeric keys. If
the password is incorrect, the message ERROR 1 will appear on the screen and the equipment will issue a sound signal.
The password is written on an adhesive label on the memory card as standard.
The menus displayed will be:
1- SETUP SYSTEM:Allows for the following to be configured: date/time, relays, channels and language.
2- SETUP CODES: Allows for registrations, cancellations, killpass and discounts to be made
3- SETUP APB:
Allows for the anti-passback timer to be configured and reset.
4- EVENTS:
Allows for events to be displayed and deleted.
The menu is changed using  . To validate each option, press ENTER.
Menu movement key
 
Menu entry key

ENTER
Menu entry or option validation key
ESC
Cancellation Key
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals will be given.
1247005v1-2.indd 19
ACCESS-1000 / ACCESS-2000
ACCESS-1000 / ACCESS-2000
868.35MHz
High-security rolling code
1000 codes (extendible to 2000) / 2000 codes
2000 codes
2 extendible to 4
Configurable on the 4 relays (assignable only to 1 relay)
Only available on proximity equipment with alarm function
230Vac / 12Vac/dc
11V –- -19V dc
8 V – 14 V ac
1A
27mA / 57mA to 230Vac
150mA/550mA to 12V ac/dc
CR 2032 3Vdc (date/time/events)
BUS-L
-20ºC to +85ºC
IP42
170x100x40mm
220x220x75mm
19
19/05/2010 11:09:49

Publicité

loading

Ce manuel est également adapté pour:

Access-2000