b) Indicating position
Enter the position number required and press ENTER. Press ENTER so that the controller is ready to receive a code and the
message LEARNING.. will appear on the screen. Once the code has been programmed, the controller automatically jumps to the
next free memory position and is then ready to receive new codes.
To exit the menu, press ESC.
c) Indicating code
Press ENTER and the controller chooses the first free position in its memory. Enter the code number to be programmed and press
ENTER. The controller will issue a sound signal indicating that the operation has been successfully completed.
d) Without indicating the position or code
Press ENTER and the controller chooses the first free position in its memory. Press ENTER so that the controller is ready to
receive a code and the message LEARNING.. will appear on the screen. Once the code has been programmed, the controller
automatically jumps to the next free memory position and is then ready to receive new codes.
To exit the menu, press ESC.
If the code being programmed already exists in the memory, the controller will display ERROR 3 on the screen and will jump to
the programmed memory position, issuing a sound signal.
If the memory position selected is occupied, ERROR 4 will appear on the screen and the controller will jump to the next free
position, issuing a sound signal.
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.
2.1.2 RANGE
This allows for sequential registrations to be made, selecting the initial memory position, initial code and number of transmitters
to be programmed.
a) Indicating position, amount and code
Enter the initial position number required and press ENTER. Enter the number of codes to be programmed and press ENTER.
Enter the initial code number to be programmed and press ENTER. When ENTER is pressed, the controller checks whether the
memory space indicated is available and makes the appropriate registrations, showing the sequential codes being programmed
on the screen.
To exit the menu, press ESC.
b) Indicating position and amount
Enter the position number required and press ENTER. Enter the number of codes to be programmed and press ENTER. When
ENTER is pressed again, the controller checks whether the memory space indicated is available and remains ready to receive a
code. The message LEARNING.. will appear on the screen. Once the first code has been programmed, the controller automati-
cally makes the appropriate registrations, showing the sequential codes being programmed on the screen.
To exit the menu, press ESC.
c) Indicating amount and code
Press ENTER and the controller chooses the first free position in its memory. Enter the number of codes to be programmed
and press ENTER. Enter the code number to be programmed and press ENTER. When ENTER is pressed, the controller checks
whether the memory space indicated is available and makes the appropriate registrations, showing the sequential codes being
programmed on the screen.
To exit the menu, press ESC.
d) Indicating the amount only
Press ENTER and the controller chooses the first free position in its memory. Enter the number of codes to be programmed and
press ENTER. When ENTER is pressed again, the controller checks whether the memory space indicated is available and remains
ready to receive a code. The message LEARNING.. will appear on the screen. Once the first code has been programmed, the
controller automatically makes the appropriate registrations, showing the sequential codes being programmed on the screen.
To exit the menu, press ESC.
Warning: According to the number of registrations to be made, this operation may take several minutes.
If there is no space available, the controller will show ERROR 6 on the screen and will issue a sound signal. No code will be
programmed.