6 Installation
Install the pump with 30m (98ft) pressure
head in places protected from heavy rain.
The device should be assembled vertically.
Any other position could impair the
performance of the appliance.
6.1 Opening of the 30m delivery
head pump casing
The side casing must be dismantled for any removal
or replacement operation of the tank. Unscrew the 4
screws and remove the casing.
Fig. 1
MNVCWAS_2222_EN
6.2 Fastening of the metal cage
Take special care when attaching and
fastening down the apparatus. If it is to be
attached to a concrete surface you must use
dowel pins with a traction torque rating of
at least 0.4kN each. You are advised to use
screws with a 6mm diameter and at least
50mm long. If the surface is metal, use M8
class A4-70 screws and with such a length
to guarantee at least 6 rotations of the
held thread. The fastening system must be
capable of supporting at least 4 times the
weight of the entire equipment, including
the tank completely full of water.
For the version with 5 litre tank only,
fastening is possible on a pole using the
specific accessories.
Fig. 2