6.8.2 Pump with 5m (16ft) delivery

Fill the tank with water and insert it in the metal cage.
Insert the pump in the tank and close the cap.
The system is ready to be powered.

6.8.3 Pump with 11m (36ft) delivery

Adjust the level switch (6.8.1 Adjustment of the level
switch position, page 10).
Fill the tank with water and insert it in the metal cage.
Insert the pump and the level switch in the tank and
close the cap.
The system is ready to be powered.

6.8.4 Pump with 30m (98ft) delivery

Avoid contact with the delivery hose
coupling of the pump. Hot surfaces may
cause personal injury if touched.
Adjust the level switch (6.8.1 Adjustment of the level
switch position, page 10).
Fill the tank with water and insert it in the metal cage.
Ensure that the male/female hydraulic joint (01) is
inserted correctly. Insert the level switch in the tank
and close the cap. Check the delivery hose coupling
of the pump (02) to make sure a small quantity of
water comes out.
01
Fig. 12
MNVCWAS_2222_EN
02
Unscrew the knurled nut (01) from the delivery joint
(02). Insert the knurled nut on the delivery pipe (03).
Insert the end of the delivery pipe into the spinner
(04). Lock the nut to the coupling.
02
Fig. 13
At the end of the installation operations, re-assemble
the casing working in the reserve order (6.1 Opening
of the 30m delivery head pump casing, page 7).
Pay attention to the fixing. Tightening
torque: 7Nm.
The system is ready to be powered.