ELECTRICAL SPECIFICATIONS

DC Voltage (DCV)
Range
2 0 0 m V
2 V
2 0 V
2 0 0 V
1 0 0 0 V
Input resistance:
Overload protection: 200mV range: 250V DC/AC peak value;
AC Voltage (ACV)
Range
2 0 0 m V
2 V
2 0 V
2 0 0 V
70 0 V
Input resistance:
Frequency response: less than 200V range from 40 to 400Hz;
Overload protection: 200mV range: 250V DC/AC peak value;
Response calibrated by sine wave RMS.
DC Current (DCA)
Range
2 0 0 µA
2 mA
2 0 mA
2 0 0 mA
10A (15 sec.)
Max. measuring voltage drop: 200mV
Overload protection:
Resolution
1 0 0 µ V
1 m V
1 0 m V
1 0 0 m V
1 V
10 Mohm for all ranges.
other ranges: 1000V DC/AC peak value.
Resolution
1 0 0 µ V
1 m V
1 0 m V
1 0 0 m V
1 V
10 Mohm for all ranges.
700V range from 40 to 200Hz.
other ranges: 1000V DC/AC peak value.
Resolution
0,1 µ A
1 µA
1 0 µA
1 0 0 µA
1 0mA
0,2A/250V fast melt fuse
10A not fused
15
Accuracy
± 0 , 5 % + 3 d i g i t
± 0 , 5 % + 3 d i g i t
± 0 , 5 % + 3 d i g i t
± 0 , 5 % + 3 d i g i t
± 1 , 0 % + 5 d i g i t
Accuracy
± 1,2% + 3 d i g i t
± 0 , 8% + 3 d i g i t
± 0 , 8% + 3 d i g i t
± 0 , 8% + 3 d i g i t
± 1 , 2% + 5 d i g i t
Accuracy
± 0,8% + 3 d i g i t
± 0 , 8% + 3 d i g i t
± 0 , 8% + 3 d i g i t
± 1,2% + 4 d i g i t
± 2,0% + 5 d i g i t
I