D.5 Sortie Des Réglages D'appareil; D.6 Réalisation D'une Mesure - Rohde & Schwarz NRT Manuel D'utilisation

Table des Matières

Publicité

NRT
D.5
Sortie des réglages d'appareil
Les réglages effectués dans l'exemple de l'annexe D.3 sont sortis ici. Les instructions abrégées ont été
utilisées.
REM -------------------------- Read out device settings -------------------------
CALL IECOUT("FREQ?")
CALL IECIN(CRfrequency$)
CALL IECOUT("INP1:PORT:SOUR:AUTO?")
CALL IECIN(Direction$)
CALL IECOUT("INP1:PORT:POS?")
CALL IECIN(Measpos$)
CALL IECOUT("SENS1:POW:REF?")
CALL IECIN(Reference$)
CALL IECOUT("SENS1:FUNC:STAT? 'POW:FORW:AVER'")'Request status of average
CALL IECIN(FunctionState$)
CALL IECOUT("UNIT1:POW:REL?")
CALL IECIN(Unit$)
CALL IECOUT("UNIT1:POW:REL:STAT?")
CALL IECIN(UnitState$)
REM -------------------------- Display values on screen --------------------------
PRINT "CR frequency:"; CRfrequency$
PRINT "Forward direction:"; Direction$
PRINT "Reference plane:"; Measpos$
PRINT "Reference value:"; Reference$
PRINT "Status for average measurement:"; FunctionState$
PRINT "Relative unit:"; Unit$
PRINT "Relative unit active:"; UnitState$
REM********************************************************************************
D.6
Réalisation d'une mesure
REM -------------------------- Example for performing a measurement -------------
CALL IECOUT("SENS1:FUNC:CONC OFF")
CALL IECOUT("SENS1:FUNC 'POW:FORW:AVER:BURS'") 'Switch on average burst measurement
REM -------------------------------- Perform measurements -----------------------
NumberMeasurements% = 10
FOR I% = 0 TO NumberMeasurements%
CALL IECOUT("SENS1:DATA? 'POW:FORW:AVER:BURS'") 'Request result arrived
CALL IECIN(Result$)
REM -------------------------- Display Result -----------------------------------
PRINT "Result"; I%; ": "; Result$
NEXT I%
REM********************************************************************************
1080.9506.02
Exemples de programmation
'Request frequency settings,
'input value.
'Request definition of forward
'direction,
'input value.
'Request def. of reference plane,
'input value.
'Request reference value of
'forward power,
'input value.
'measurement,
'input value.
'Request relative unit,
'input value.
'Request unit status,
'input value.
'Only one measuring function can
'be active.
'function.
'last.
'Call result.