IMPORTANT: This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Since each application is unique, it is the responsibility of
the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use. Please consult the manual and/or a qualified technician for further information.
Operator Mounting
1a
Wall Mount: The operator should generally be installed below the door shaft, and
as close to the door as possible.
1b
Bracket Shelf Mounting: The operator may be mounted either above or below the
door shaft.
NOTE: The optimum distance between the door shaft and operator drive shaft is
12 – 15 inches.
2
Place door sprocket on the door shaft. Do not insert the key at this time.
Place drive sprocket on the appropriate side of the operator. Do not insert the key
3
at this time.
4
Wrap chain drive around door sprocket and join roller chain ends together with
master link.
Raise operator to approximate mounting position and position chain over operator
5
sprocket.
The optimum distance between the door shaft and operator drive shaft is 12" – 15"
6
which allows for 1/2" to 3/4" of chain movement at the center. Make sure the
operator output shaft is parallel to door shaft and sprockets are aligned. When in
position, secure the operator to wall or mounting bracket.
7
Align sprockets, insert key into keyway, and secure.
8
Place hand chain around hand chain wheel.
Run the power wires through the power wiring conduit hole in the electrical box
9
enclosure. Connect the power to the operator. Connect the earth ground to the
ground screw in the electrical box enclosure. Follow ALL national and local
electrical codes.
Adjust the limit switches to open and close door properly. Make sure the limit nuts
10
are positioned between the limit switches before proceeding with adjustments.
Remove cotter pin from nut on the clutch shaft. Back off clutch nut until there is
11
very little tension on the clutch spring. Tighten clutch nut gradually until there is
just enough tension to permit the operator to move the door smoothly but to allow
the clutch to slip if the door is obstructed. When the clutch is properly adjusted, it
should generally be possible to stop the door by hand during travel. Reinstall
cotter pin when finished.
12
Radio programming instructions inside cover of operator.
Inside the Electrical Box
9
Single Phase Connections
Three Phase Connections
HOT
NEUTRAL EARTH
Follow ALL national and
local electrical codes.
L1 L2
Power wiring ONLY!
DEDICATED CIRCUIT
POWER WIRING
POWER WIRING
USE COPPER WIRE ONLY
14 AWG Minimum
for the model H/J door operator
1a
Right Hand Wall Mounted Operator
10
L1 L2
L3
DEDICATED
CIRCUIT
USE COPPER WIRE ONLY
Direction Limit Nut Will Move During Travel
1b
Bracket Shelf Mounted Operator
OPTIONAL
Mounting Bracket
P/N 08-9098
Optimum Distance
12-15"
7
Align Sprockets
Limit Switches
Retaining
Plate
Limit Nuts
Push
WARNING: This product can expose you to chemicals including lead, which
are known to the State of California to cause cancer or birth defects or other
reproductive harm. For more information go to www.P65Warnings.ca.gov
Manual Operation
This operator has provisions for manually operating the door in case of emergency
or power failure. This includes both a floor level disconnect chain to disconnect the
door from the door operator and a disconnect chain with manual hoist to electrically
disable the operator controls. Turn off power to the operator BEFORE manually
operating your door.
a
To operate the hoist, pull the disconnect chain (small chain) to engage the hoist
mechanism. The disconnect chain may be locked in position by slipping the
end through the keyhole of the chain keeper mounted on the wall. Operate the
door in the desired direction by pulling on one side or the other of the continu-
ous loop hoist chain (large chain). The disconnect chain must be released from
the chain keeper before the door will operate again electrically.
b
For manual operation, pull the floor level disconnect chain and secure in the
disengaged position by slipping the end through the keyhole bracket mounted
on the wall. If an emergency egress device is used, pull handle to disengage
operator from door. The door may now be pushed up or pulled down manually.
Release the disconnect chain to operate the door again electrically.
Optimum
Distance
12-15"
a
Electrical Interlock with Hoist - "H"
Close door
before
disengaging
operator.
Be sure door sprocket
is properly aligned with
drive before securing
to the shaft.
NOTE: For maximum
operator life, keep the
drive sprocket closer
to the chassis.
b
Manual Disconnect - "J"
Keyhole Bracket
Chain Keeper
(4 ft. above floor)
LOGIC 5
Chain Keeper
(with pad locking provisions)
Mount Chain
Keeper 4'
above floor

Publicité

loading

Sommaire des Matières pour LiftMaster Elite LOGIC 5 Serie

  • Page 1 QuickStart LOGIC 5 for the model H/J door operator WARNING: This product can expose you to chemicals including lead, which IMPORTANT: This QuickStart is intended to highlight a typical installation. These instructions are not intended to be comprehensive. Since each application is unique, it is the responsibility of are known to the State of California to cause cancer or birth defects or other the purchaser, designer, installer and end user to ensure that the total door system is safe for its intended use.
  • Page 2 7. Turn selector to T, TS or FSTS wiring types. FSTS FSTS to clear the MAS counter. STOP DIAG DIAG NOTE: Must have at least one LiftMaster Monitored 6. Turn selector back to selected wiring type. OPTN OPTN Entrapment Protection (LMEP) device installed. PROG PROG...
  • Page 3 Installation rapide LOGIC 5 Pour l’ouvre-porte de Modèle H/J AVERTISSEMENT : Ce produit peut vous exposer à des produits chimiques comme le plomb, reconnu par l’État de la Californie comme cause de cancers, IMPORTANT : Ce démarrage rapide est destiné à mettre en valeur une installation typique. Ces instructions ne se veulent pas exhaustives. C'est parce que chaque application est d’anomalies congénitales et d’autres problèmes liés à...
  • Page 4 Le dispositif de protection surveillée contre l'emprisonnement de Liftmaster Le cadran du sélecteur (Liftmaster Monitored Entrapment Protection ou LMEP) est exigé pour la plupart CÂBLAGE DES CONTRÔLES 20 AWG ou plus des paramètres programmables.Capteurs photoélectriques Thru-Beam (montrés). UTILISER DU FIL DE CUIVRE SEULEMENT du tableau est réglé...

Ce manuel est également adapté pour:

Elite logic 5 hElite logic 5 j