Replacing the HEPA Primary Filter
IMPORTANT: Performance is reduced when a non-Legend
Brands primary filter is installed. For maximum filtration
performance, use only Legend Brands filters. Do not clean
and reuse the HEPA filter. Always replace the prefilter when
replacing the HEPA filter.
1.
Lay unit on its back and release the four (4) buckles. Lift
off the filter door.
2.
Remove the prefilter from the filter door and discard.
3.
Release the two locking tabs and lift out primary filter
element. Discard used filter.
4.
Replace HEPA primary filter, handling it with care, as filter
is easily damaged. Do not use a filter that is damaged.
5.
Place new prefilter(s) in filter door. Replace filter cover and
lock the four buckles securely.
Before each use
Inspect the electrical cord for damage, and do not use the unit
if you find any fraying, cuts, etc. Contact your local distributor
for service.
Filter Options
Air Filtration Applications:
Water loss air filtration and mold
remediation*
Standard air scrubbing. For high particle
loads, such as construction or remodeling sites.
Odor control and air filtration. For removing
volatile organic compounds (VOCs), fumes from
paint and paint thinners, and many other
noxious odors, eg, from food, sewage, etc.
Smoke particulate and odor removal. Paper
prefilter and HEPA filter remove particulates
and carbon filter adsorbs odors.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for
help"
124775B HEPA 700
As Needed
Clean exterior of housing and inside the filter compartment.
Ensure housing is completely dry before reassembling. Do not
apply liquids to control panel or to any electrical components.
When using the HEPA 700 for remediation or in
sensitive environments:
• Wear NIOSH-approved protective gear when changing
filters.
• Change both filters after every remediation job.
• Dispose of used filters according to local regulations.
• Replace both the prefilter and HEPA filter to prevent
cross-contamination.
• Clean the unit thoroughly (vacuum and damp wipe per
IICRC S520, 10.11) before removing it from the
containment area to avoid cross-contamination. Let the
unit dry before installing clean filters.
For parts and service contact your local distributor or
Legend Brands: Live Chat - Info.legendbrands.com |
Email:
Service@legendbrandsrestoration.com
Prefilter(s)
Specialty Prefilter
Removes larger
particulates – protects
primary filter
2-in. MERV 8 Pleated
Paper Filter
#125026 (6 pk.)
1-in. MERV 8 Pleated
Paper Filter
#125029 (12 pk.)
SPECIFICATIONS
Specifications are subject to change without notice. Some values may
be approximate.
Model
Airflow
Static pressure
Weight
Dimensions
(H × D × W)
Amps/Power
Power cord
Duct size
Construction
Xactimate
Safety
Specifications are subject to change without notice. Some values
may be approximate.
3
Primary filter (HEPA)
Carbon removes
Removes fine particulate
VOCs and odors
down to .3 microns
#124966 (1 pk.)
1-in. Activated
#124966 (1 pk.)
Carbon Filter
#145028 (8 pk.)
#125027 (4 pk.)
HEPA 700 (#125105)
Variable to 700 CFM | 1189 CMH
3.0 in. (H
O) | 747 Pa
2
42.0 lbs. | 19.1 kg
22.8 × 17.0 × 25.9 in.
57.9 × 43.3 × 65.9 cm
1.5 - 3.0 amps, 115v, 60 Hz, 350w
25 ft. | 7.6 m
14 in. | 35.6 cm
Injection-molded plastic housing
WTRNAFAN>
ETL listed to UL 507 and CSA C22.2 No. 113