Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

The HEPA 700 draws air in from the surrounding environment and passes it through an advanced filtration
system. The unit removes airborne particles such as dust, mold spores, pollen, pet dander and other debris, and
odors, and can be configured for negative or positive-pressure filtration setups.
R E A D A N D U N D E R S T A N D B E F O R E O P E R A T I N G
ELECTRIC SHOCK HAZARD
The unit must be electrically grounded. Use only on
GFCI protected receptacles.
Connect to a properly grounded outlet only. Do not cut
off the grounding prong. Do not use with an adapter.
Do not use with extension cords.
Do not use with damaged cord or plug. If unit is not working as
it should, has been dropped, damaged, left outdoors, or
exposed to water, return it to an authorized service center for
repair.
Unplug cord from outlet when not in use or when servicing unit.
ELECTRIC SHOCK HAZARD
Keep motor and electrical parts dry.
Do not use outdoors. For indoor use only.
Do not handle plug or unit with wet hands.
Do not operate unit in standing water.
BREATHING HAZARD
When using the HEPA 700 in a containment area, turn
off all sources of power to open combustion
appliances such as fireplaces, boilers, furnaces, water
heaters and HVAC systems to avoid the risk of backdrafting
deadly carbon monoxide fumes.
Parts Identification
Filter cover buckle
(×4). Release to
replace filter
elements.
Air intake
ring. Attach
14 in. semi-
rigid ducting.
Inlet and
inlet cover.
Remove
cover
before
operating.
124775A HEPA 700
Owner's Manual
HEPA 700 Air Scrubber
Control panel.
WARNING: This product may expose you to
chemicals, including lead and phthalates, known to the
State of California to cause cancer, birth defects, or other
reproductive harm. For more information, go to
P65Warnings.ca.gov
HEPA 700 APPLICATIONS
Water Damage
Construction Dust Control
Mold Remediation
Odor control
Other uses: The HEPA 700 can be used for dust
abatement, fire damage remediation, jobsite ventilation,
and positive or negative air setups for contamination
cleanup and cleanroom environments. Use in homes,
businesses, institutions, schools, hospitals, long term care
facilities, construction and remodel job sites.
NOTICE! Many of these applications can present
significant health risks and require professional training.
Because federal, state/provincial, and local laws
and regulations have varying requirements for the
application, testing and general use of equipment on
asbestos abatement projects, Legend Brands cannot
warrant products for asbestos abatement. Contractors
performing abatement work should evaluate tools,
equipment and procedures in light of their local regulatory
requirements, and comply with those requirements.
Carry handle.
Folds down when
not in use.
Feet for
horizontal
operation &
stacking.
115V outlets
(×2) and
breaker reset
switch.
Use the hook-and-pile
fasteners to attach the inlet
cover here while unit is use.
1
Filtered air
outlet. Filter
retainer ring may
be used to
attach 14 in.
layflat ducting.
Legend Brands, Inc.

Publicité

loading

Sommaire des Matières pour Dri-Eaz HEPA 700

  • Page 1 Owner’s Manual HEPA 700 Air Scrubber The HEPA 700 draws air in from the surrounding environment and passes it through an advanced filtration system. The unit removes airborne particles such as dust, mold spores, pollen, pet dander and other debris, and odors, and can be configured for negative or positive-pressure filtration setups.
  • Page 2 Stacking for Storage and Operation Regularly check and replace the prefilter(s) and HEPA Stack the HEPA 700 up to three high for storage or transport. primary filter as needed. The control panel will indicate Secure the units when stacked for transport.
  • Page 3 Legend Brands filters. Do not clean apply liquids to control panel or to any electrical components. and reuse the HEPA filter. Always replace the prefilter when When using the HEPA 700 for remediation or in replacing the HEPA filter. sensitive environments: Lay unit on its back and release the four (4) buckles.
  • Page 4 115 V (×2) et interrupteur de Admission et réenclenchem couvercle ent du d’admission. disjoncteur. Retirez le couvercle avant Utilisez les attaches à bande Velcro l’utilisation. pour fixer le couvercle d’admission ici pendant que l’unité est en service. 124775B HEPA 700 Legend Brands, Inc.
  • Page 5 équipement et leurs procédures en fonction de leurs exigences réglementaires locales et s’y conformer. Prises électriques Vous pouvez connecter jusqu'à huit (8) HEPA 700, à la vitesse la plus basse, sur un circuit de 15 ampères; quatre (4) à la AVANT DE COMMENCER vitesse la plus élevée.
  • Page 6 Au sujet des filtres restauration. • Éliminez les filtres usés en conformité avec les règlements IMPORTANT : N’utilisez que des filtres HEPA 700 de la municipaux. marque Legend Brands. Les performances sont réduites • Remplacez le préfiltre et le filtre HEPA afin de prévenir la lorsqu'un filtre primaire d’une marque autre que Legend...
  • Page 7 115 V, 60 Hz Intensité de courant 1,5 - 3,0 A POUR OBTENIR DES PIÈCES OU UNE INTERVENTION DE Puissance 350 W SERVICE, VEUILLEZ COMMUNIQUER AVEC VOTRE Cordon d’alimentation DISTRIBUTEUR LOCAL 25 pi | 7,6 m 124775B HEPA 700 Legend Brands, Inc.
  • Page 8 Depurador de aire HEPA 700 El HEPA 700 aspira el aire del entorno y lo hace pasar a través de un avanzado sistema de filtración. La unidad elimina partículas en el aire como polvo, esporas de moho, polen, caspa de mascotas y otros desechos y olores, y se puede configurar para montajes de filtración de presión positiva o negativa.
  • Page 9 áreas de contención de presión negativa. APLICACIONES HEPA Apilamiento para el almacenamiento y el funcionamiento Apile el HEPA 700 hasta tres alturas para su almacenamiento o • Daños por agua transporte. Asegure las unidades cuando las apile para su •...
  • Page 10 4. Para sustituir el filtro primario HEPA, proceda al siguiente Cuando utilice el HEPA 700 para la remediación o en paso. De lo contrario, vuelva a colocar el conjunto del filtro ambientes sensibles: en la unidad y vuelva a colocar las cuatro hebillas.
  • Page 11 Opciones de filtro El HEPA 700 puede establecerse en una variedad de configuraciones de filtro para requerimientos específicos de limpieza de aire. Utilice la siguiente tabla para encontrar la mejor configuración de filtración para su proyecto. Aplicación de filtración de aire:...

Ce manuel est également adapté pour:

125105