Service - clage K 5 Mode D'emploi

Masquer les pouces Voir aussi pour K 5:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

K 5

Service

Service
A thermal cutout is installed in the appliance to prevent it overheating. If the appliance generally does not heat
the water, this thermal cutout may have been tripped.
Unplug the power cable and fill the appliance. Wait for approx. 3 minutes, then plug the cable into the socket
outlet.
If the thermal cutout is subsequently tripped again, a malfunction may have occurred and must be repaired by a
qualified specialist.
Important:
In all other cases, unplug the power cable and call a qualified specialist to repair the malfunction.
Mains power cable
If the connection cable is damaged, it must be replaced with an original spare cable from the manufacturer by an
authorised technician in order to avoid any hazards (available as spare part).
PE
PE
Netzklemme
Mains terminal
Heizung
Heating
d
KPR
d
KPR
Temperatursicherung
Thermal cutout
Temperature limiter
Temperaturwählbegrenzer
TWB
TWB
Heizung 2000 W
Heating 2000 W
Boiling point controller
Kochpunktregler
d
KPR
(KPR)
20
Kontroll-
Indicator
lampe

Publicité

Table des Matières
loading

Table des Matières