Preparative for Installation
Selection of the Installation Location
WARNING!
The unit must be installed where strong enough to withstand the weight of the unit and fixed
securely, otherwise the unit would topple or fall off.
CAUTION!
● Do not install where there is a danger of combustible gas leakage.
● Do not install the unit near heat source, steam, or flammable gas.
● Children under 10 years old must be supervised not to operate the unit.
● Appliance shall be installed, operated and stored in a room with a floor area larger than
2
"X"m
(see table 1).
Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people andmaterial.
Details to this refrigerant are found in chapter "refrigerant".
Decide the installation location with the customer as follows:
Indoor Unit
1. Obstruct should be put away from the intake or outlet vent of the indoor unit so that the
airflow can be blown through all the room.
2. Make sure that the installation meets the requirement of the schematic diagram of
installation spaces.
3. Select the place where can stand 4 times of the weight of the indoor unit and would not
increase the operating noise and vibration.
4. The horizontality of the installation place should be guaranteed.
5. Select the place where is easy to drain out the condensate water, and connect with
outdoor unit.
6. Make sure that there are enough space for care and maintenance, and the height fall
between the indoor unit and ground is above 2300mm.
7. When installing the suspension bolt, check if the installation place can stand 4 times of the
weight of the unit. If not, reinforce it before installation.
Note:
There will be large amount of greasy
dirt accumulated on the fan, heat
exchanger and water pump located in
the dinning room and kitchen, which
would reduce the capacity of the
heater exchanger, lead to leakage
and abnormal operation of the water
pump.
≥1500mm
10
≥20mm
≥2300mm
≥1500mm
Fig.1