Télécharger Imprimer la page

Kemper MaxiFil Clean Notice D'utilisation page 62

Masquer les pouces Voir aussi pour MaxiFil Clean:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 79
Lack of or insufficient compressed air supply.
Connect the power cable to the on-site air compressed air
network. Required compressed air 5–6 bar, clean, dry and oil-
free.
Signal lamp blinks briefly 5x in a row at regular intervals:
Dust collection cartridge missing or filled with dust particles.
Built in regulator for run-on time in start-stop operation (item 3)
If a start-stop sensor (optional) has been connected, the extraction
system run-on time can be adjusted to between 5 and 60 seconds after
completion of the welding process.
Maintenance socket (item 4)
Connection facility for manufacturer's service department. Our service
department can carry out adjustments to the product using this
interface.
NOTE
Signal horn (item 5)
Reliable capture of welding fumes is only possible with sufficient
extraction capacity. As the dust accumulation in the filter increases, its
resistance to through-flow increases and the suction decreases.
As soon as it drops below a minimum value, the signal horn will sound.
A filter change is now required.
The same happens if the damper flap in the extraction hood is closed
too far and the extraction capacity is reduced too much.
This situation can be remedied by opening the damper flap.
Pressure measurement opening (item 6)
Connection facility for manufacturer's service department. Our service
department can take pressure measurements using this connection.
Pressure switch (items 7 and 8)
May only be used by manufacturer's service department.
1502827-03
- 62 -
EN

Publicité

loading

Ce manuel est également adapté pour:

67 150 10367 150 10467 150 105