Operating Mode Selection - Zehnder Alura LCD Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
1 - Standby mode indicator
2 - Operating mode
3 - Programme
4 - Automatic mode (base unit)
5 - Information (temperature, time, etc.)
6 - Day indicator
7 - Programme status (Comfort / Eco)
8 - Time setting indicator
Your control panel helps you understand the energy consumption level
which corresponds to your chosen temperature level. The cursor is placed
opposite the coloured block which corresponds to the energy consumption level
of this setpoint temperature.
NOTE:
The screen light automatically goes out after 30 seconds without any key being
pressed. This standby function does not affect the operation of your radiator,
and pressing any key will reactivate the light.

3.3 Operating mode selection

There are 4 operating modes (Frost protection, Eco, Comfort, Auto) available,
by pressing the MODE repeatedly. These are supplemented by 3 pre-set programmes
and one user programme (see chapter 3.4).
A heating indicator informs you that your radiator is
heating when the desired temperature set on your
radiator or your programming base unit exceeds the room
temperature measured by your radiator.
34
9 - Activation/deactivation of Open window
detection function
10 - Override indicator
11 - Energy consumption indicator
12 - Lock indicator
13 - Setting parameters
14 - Heating indicator
15 - Timer indicator
radiator heating indicator
FrOST PrOTECTION mODE INDICATOr
Your radiator maintains a minimum room temperature of 7°C to prevent any risk
of frost.
This temperature cannot be modified by the user.
This mode is recommended when the room is unoccupied for periods longer
than 24 hours.
ECO mODE INDICATOr
This economic mode lowers the temperature by approximately 3.5°C compared
to the desired temperature level for the COMFORT mode.
This temperature cannot be modified by the user. It cannot exceed 19°C.
This mode is recommended when the room is unoccupied for periods longer
than 2 hours.
Operating example: if your radiator is set to 20°C in COMFORT mode, the ECO
mode setpoint temperature will be 16.5°C.
COmFOrT mODE INDICATOr
This is your radiator's normal operating mode. You can select your desired room
temperature using the – or + adjustment keys.
This temperature level can be adjusted between 7 and 28°C in 0.5°C increments.
This mode is recommended when the room is occupied.
rEmINDEr:
The setpoint temperature can be adjusted in COMFORT mode; the temperature
in ECO mode will be the same as the Comfort mode -3.5°Cen mode ÉCO sera celle
du mode Confort -3.5°C.
lOAD-ShEDDINg INDICATOr
When your installation has a load-shedding system
connected at the pilot wire input, it may send a priority
command to your radiator. Your appliance then displays
the information shown opposite.
The appliance's operating mode cannot be modified
during load-shedding.
40008126
40008126
EN
Load-shed-
Operating mode
ding mode
interrupted
Using your appliance 35

Publicité

Table des Matières
loading

Table des Matières