Code
Parameter
Additional amplifier: Default setting: 2
07
0 = inactive
1 = soft
9 = loud
In case the additional 15 V power supply is available, you may
activate the additional amplifier, hence voice-controlled two-way-
communication and set the desired volume via this configuration
step code. In case the additional power supply is not available or
blacks out, Behnke Series 10 Intercom stations will automatically
return to their standard full-duplex operations mode.
Operations modes Relay: Default setting: 4
08
0 = inactive
1 = to be activated via the telephone
4 = to be activated via the telephone & disconnecting after
activation
7 = activated during outgoing calls
8 = activated during incoming calls
9 = activated during both incoming and outgoing calls
10 = activated at the beginning of an outgoing call
11 = activated at the beginning of an incoming call
12 = activated at the beginning of both outgoing and incoming
calls
16 = activated during a direct call via button 1
17 = activated at the beginning of a direct dial from button 1
18 = manually activated
When using operations mode 18, activation code 1 (configuration
step 10) will turn the relay off and activation code 2 (configuration
step 11) will turn the relay on.
Relay activation time: Default setting: 3
09
1 = 1 second
2 = 2 seconds
30 = 30 seconds
Use this configuration step to adjust the relay activation interval
for operations modes 1, 4, 10, 11, 12 and 17 at the
beginning of the connection.
Relay activation codes: Default: cf. text
10
Activation code = 1. Activation code
11
Activation code = 2. Activation code
Activation codes consist of ciphers only and each activation code
may be up to 4 characters long. In the default settings, 0 is set for
activation code 1. There is no default setting for activation code 2.