Thermal zones
Bedrooms: advanced configuration
T1
16°C
T2
18°C
T3
20°C
3°C
Anti-freeze
06:13
Wednesday 01 March 2017
7
Save
Home
Back
Settings

Advanced configuration of a Thermal Zone

From the main screen of any Thermal Zone,
button to access the window shown in figure 7 .
tap the

Adjusting the reference temperatures (T1, T2, T3)

The temperature/times diagram has three reference values on the temperature
axis: T1, T2 and T3 .
Default settings are:
For heating: T1=16 °C, T2=18 °C, T3=20 °C
For cooling: T1=22 °C, T2=24 °C, T3=26 °C
Use commands < and > to change the reference temperatures .
The value which can be assigned to each temperature band is limited by
the values of the bands immediately above and below it. For example, if
band T3 corresponds to 20°C and band T1 corresponds to 16°C, the value
of band T2 is between 16.1°C and 19.9°C.

Adjusting the anti-freeze temperature

The heating system is default set to maintain a minimum ambient temperature of
3 .0°C to protect the system's pipes from freezing . This minimum temperature is
also ensured even when the programmable thermostat is not active .
Use the commands < and > to change the anti-freeze temperature .
The anti-freeze function is NOT active only if the control of the
thermoregulation system is COMPLETELY disabled (see the paragraph on
"Thermoregulation" on page 54).