Advanced configuration of a Thermal Zone
From the main screen of any Thermal Zone,
button to access the window shown in figure 7 .
tap the
Adjusting the reference temperatures (T1, T2, T3)
The temperature/times diagram has three reference values on the temperature
axis: T1, T2 and T3 .
Default settings are:
For heating: T1=16 °C, T2=18 °C, T3=20 °C
For cooling: T1=22 °C, T2=24 °C, T3=26 °C
Use commands < and > to change the reference temperatures .
The value which can be assigned to each temperature band is limited by
☞
the values of the bands immediately above and below it. For example, if
band T3 corresponds to 20°C and band T1 corresponds to 16°C, the value
of band T2 is between 16.1°C and 19.9°C.
Adjusting the anti-freeze temperature
The heating system is default set to maintain a minimum ambient temperature of
3 .0°C to protect the system's pipes from freezing . This minimum temperature is
also ensured even when the programmable thermostat is not active .
Use the commands < and > to change the anti-freeze temperature .
The anti-freeze function is NOT active only if the control of the
thermoregulation system is COMPLETELY disabled (see the paragraph on
"Thermoregulation" on page 54).