15 Données techniques
ELECTRICAL SPECIFICATIONS
Electric heater ( optional )
Type
Capacity setting
Phase
Power supply (1)
Frequency
Voltage
Running Current (back-up heater)
Current
Zmax (back-up heater)
Minimum S
Value (8)
sc
Zmax (back-up heater + booster
heater (*KHW* models))
Running Current
(backup heater +
booster heater
(*KHW* models))
Minimum S
sc
Value (8)
Voltage range
Minimum
Maximum
quantity of wires
Wiring connections
for power supply back up heater
type of wires
quantity of wires
Communication cable
type of wires
quantity of wires
User interface
type of wires
quantity of wires
Preferential kWh rate power
supply
type of wires
quantity of wires
Electricity meter
type of wires
domestic hot water pump
quantity of wires
type of wires
Power supply for optional *KHW*
quantity of wires
type of wires
quantity of wires
for connection to optional *KHW*
model + Q2L
type of wires
for connection with R5T
quantity of wires
type of wires
for connection with R6T
quantity of wires
type of wires
quantity of wires
for connection with A3P
type of wires
quantity of wires
for connection with M2S
type of wires
quantity of wires
for connection with M3S
type of wires
quantity of wires
for connection with optional FWXV*
type of wires
(demand input and output signal)
quantity of wires
for connection with bottom plate
type of wires
heater
Notes
(1) Above mentioned power supply of the hydro box is for the backup heater only. The Switch box & pump of the hydrobox are supplied via the outdoor unit. The optional domestic warm water
tank has a separate power supply.
(3) Select diameter and type according to national and local regulations
(4) For more details of the voltage range and current refer to installation manual
(5) Voltage: 230V / Maximum current: 100mA / Minimum 0,75mm²
(6) Depends on thermostat type, refer to installation manual
(7) Wire included in option *KHW*
(8) In accordance with EN/IEC 61000-3-11(*), it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys(***) ≤ Zmax
(9) Equipment complying with EN/IEC 61000-3-12 (**)
(*) : European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated current ≤ 75A.
(**) : European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A and ≤ 75A per phase.
(***) : System impedance
Guide de référence installateur
97
3V
kW
3
6
1~
3~
Hz
50
230
230
V
A
13
15,1
-
-
Ω
-
-
Ω
0,29
-
+ EK*V3
A
26 (13+13)
28,1 (15,1+13)
+ EK*Z2
A
-
-
+ EK*V3
kVA
(9)
(9)
+ EK*Z2
kVA
-
-
V
207
207
V
253
253
3G
4G
Note (3)
Note (3)
0,75 mm² till 1,25 mm² ( max length 500 m )
power : 6,3 A note (3)
signal : 0,75 mm² till 1,25 mm²(max length 50 m)
Minimum 0,75 mm² (5V DC pulse detection)
Minimum 0,75 mm² (2A in rush, 1A continuous)
Minimum 0,75 mm²
100 mA, minimum 0,75 mm²
9W
3
6
6
9
1~
1~
3~
3~
50
230
230
400
400
13
26
8,7
13
-
0,29
-
-
-
(9)
-
-
-
0,17
-
-
26 (13+13)
39 (26+13) 21,7 (8,7+13)
26 (13+13)
-
-
16,2 (8,7+7,5)
20,5 (13+7,5)
(9)
(9)
(9)
(9)
-
-
(9)
(9)
207
207
360
360
253
253
440
440
3G
3G
4G
4G
Note (3)
Note (3)
Note (3)
Note (3)
3
2,5 mm²
2
power : 2
signal : 2
2
2
3G
13A, note (3)
5G
Note (3) and (4)
Note (7)
Note (7)
2
Note (6)
Note (3) and (5)
2
Note (3) and (5)
3
Note (3) and (5)
4
2
Note (3)
3D078754_B page 2
EHBH04+08 + ERLQ004~008
Daikin Altherma - basse température Bibloc