Troubleshooting - Piusi P3.5 Installation, Utilisation Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
15.

TROUBLESHOOTING

ATTENTION
Before carrying out any inspection or maintenance operations, shut off the air and discharge the
pressure from the circuit by following the decompression procedure.
Problem
Possible cause
Intake air pressure too low
Air lines obstructed
Dispensing valves closed or obstructed
Pump does not
work
Fluid lines or other components obstructed
No fluid left in tank
Pneumatic motor damaged
Piston gaskets are worn
Pump runs
irregularly
No fluid left in tank
Continuous air
Motor gaskets not sealing properly
leakage
The pump
does not start
up and and
Pump stalled
releases air
from silencers
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
PIUSI P 3.5 - PIUSI P 5.5
Corrective action
Increase intake air pressure
Clean air lines
Open or clean dispensing valves
Check that fluid lines and components are
clean
Fill tank
Repair pneumatic motor
Replace worn gaskets
Fill tank
Clean or replace motor gaskets
Push the button RESET (see diagram after
the table)
19 /124

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P5.5

Table des Matières