To guarantee functional security, the full projection of the latchbolt must
be ensured.
All deliveries are still made on the basis of our General Terms and Conditions.
3.

Preparation for use

3.1

Safety instructions

ATTENTION
For proper functioning of the multi-point lock, the residual ripple of the
power supply must not exceed 100 mVpp.
ATTENTION
Junction boxes should be accessible for maintenance work.
Cable types, lengths, and cross sections must conform to the specifi cations.
As the cable duct to the cable guide from the door leaf into the door frame,
we recommend hidden cable ducts or the cableless electrical conductor
SECUREconnect from the GU-BKS product range.
Connect only high-quality power supply units to
the multi-point lock!
Low-quality power supply units can cause problems
in operation.
Do not crimp or damage the cables!
Make sure that the cables are laid and the electrical
connection of the multi-point lock is made with
the plug connection in such a way that the cables
cannot be crimped or damaged in the area of the
lock or faceplate during installation.